www.Pegasustech.net
3-10 UPC-A
Read:
Format
System character
Data digits (10 digits)
Check digit (1 digit)
Check digit verification:
The check digit verification is optional.
Check digit trans.:
By setting Enable, check digit will be transmitted.
Code ID setting:
Code ID is a one-or-two-character string used to represent the symbol upon a
succeeding reading. If you want application to transmit Code ID, you must set Code ID transmission to
be enabled. Refer to the chapter of
Insertion group selection:
Refer to Global insertion group selection of the chapter of
Supplement digits:
The Supplement digits barcode is the supplemental 2 or 5
characters.
Format
System character
Data digits (10 digits)
Check digit Supplement digits 2 or 5
Truncation/Expansion:
Truncate leading zeros-
The leading “0” digits of UPC-A data characters can be truncated when the
feature is enabled.
Expand to EAN-13-
It extends to 13-
digits with a “0” leading digit when the feature is enabled.
Truncate system character-
The system character of UPC-A data can be truncated when the
feature
is enabled.
Add country code-
The country code (“0” for USA) can be added when the feature is enabled.
SETUP
Option bar code
Option
Alpha. entry
Single-scan setting
Read
Disable
00
Enable
01*
Check digit verification
Disable
00
Enable
01*
Check digit trans.
Disable
00
Enable
01*
Code ID setting
00-FF
16
00-FF
16
(ASCII)
<A>*
Insert group selection
00-44
00-44
00*
Supplement digits
None
00*
29