PEERLESS PVF Series Installation And Operating Instructions Manual Download Page 4

WARNING

Overhead load

Death or serious personal injury

Motors which are provided with lifting lugs, lifting ears
or eyebolts on the top of the motor should be lifted by
these points only. They should be used to lift the entire
pump assembly.

Only lift the entire pump assembly with the lifting lugs
provided on top of the motor. Never lift unit using
hooks or slings on shafts or conduit box. Straps should
not be used to lift a pump assembly.

When manually lifting pump components, use proper
lifting techniques and never bend at the waist. Keep
the component close to your body with your back
straight, and lift with your legs.

WARNING

Crushing of hands

Death or serious personal injury

Do not work under a suspended object unless you
have taken precautions to stop its fall in the event of
lifting equipment failure. Do not place hands under a
component in such a way that it could fall on your
hands if it were dropped.

WARNING

Sharp and moving machine parts or blades.

Death or serious personal injury

Ensure an approved coupling guard is in place before
operating the product. Failure to observe this warning
could result in injury to operating personnel.

Wear appropriate protective safety equipment
including gloves when handling parts and components.

Read and follow all recommended guarding and safety
instructions for accessories, if any.

WARNING

Rotating equipment and sharp objects

Death or serious personal injury

Do not place fingers, hands, arms, etc. into any
opening (such as the air relief valve hole).

Do not wear loose or frayed clothing or jewelry that
could catch on equipment or become trapped in the
equipment.

Do not touch the impeller or other rotating elements, if
rotated, this can cause severe injury. Areas of the
pump are left open for inspection and adjustment of
packing. Never place your hands or fingers into these
areas while the equipment is in operation. Do not wear
loose clothing, long hair, or jewelry around the
equipment.

WARNING

Excessive noise

Death or serious personal injury

If the operating noise level of the product exceeds local
code or safe levels (over 85 dBA), the product must be
installed in a controlled access area. Provide ear
protection to persons authorized to be in this area.

Fire pumps can start unexpectedly at any time. Ear
protection should be carried by, or readily available to,
all persons authorized to be in the pump room with
these pumps. Observe health and safety regulations
limiting exposure of personnel to excessive noise.

Partial decomposition of fluoro-elastomers (when fitted)
will occur if equipment reaches temperatures above 400
°F (205 °C).

FM

For applications involving potentially explosive
atmospheres, contact Peerless Pumps for more
information.

Avoid rapid temperature change in the pumped liquid.
Thermal shock from sudden temperature changes can
damage pump components.

Pumps are not designed to accept external loads from
belt-driven arrangements. A separate jackshaft with a
bearing structure suitable for belt loading is required.

Do not remove or paint over any safety labels. If labels are
lost or damaged, contact your Peerless Pump
representative for replacement.

Do not use gland packing when pumping hazardous
liquids.

Do not use the pump as a support for pipes. Do not mount
expansion joints, so that their force, due to internal
pressure, acts on the pump flange, without written
authorization from Peerless Pumps.

1.6 Material safety data sheet

As a general practice, material safety data sheets (MSDS) are not
supplied with pumps unless required. They may be requested from
Peerless Pump.

1.7 Noise level

WARNING

Excessive noise

Death or serious personal injury

If the operating noise level of the product exceeds local
code or safe levels (over 85 dBA), the product must be
installed in a controlled access area. Provide ear
protection to persons authorized to be in this area.

Fire pumps can start unexpectedly at any time. Ear
protection should be carried by, or readily available to,
all persons authorized to be in the pump room with
these pumps. Observe health and safety regulations
limiting exposure of personnel to excessive noise.

6

English (US)

Summary of Contents for PVF Series

Page 1: ...PVF Vertical inline single stage pumps Installation operation and maintenance manual English Peerless_USLetter_Front_PVF IO fm Page 1 Friday September 13 2019 10 38 PM...

Page 2: ...or wear caused by abrasive materials nor does it cover damage resulting from misuse accident neglect or from improper operation maintenance installation modification or adjustment This warranty does...

Page 3: ...Before starting any work on the product make sure that the power supply has been switched off and that it cannot be accidentally switched on Never do maintenance work on the pump when it is connected...

Page 4: ...Excessive noise Death or serious personal injury If the operating noise level of the product exceeds local code or safe levels over 85 dBA the product must be installed in a controlled access area Pr...

Page 5: ...10 11 12 6 13 14 20 21 22 15 16 17 18 19 6 6 6 6 TM060290 Fig Pump nameplate Pos Description Pos Description 1 Product number 12 Description 2 Nominal flow 13 Description 3 Nominal pressure 14 Serial...

Page 6: ...nd FM approved Approvals B cFMus approved C UL listed approved D NFPA compliant E ULC approved F CCC X Special 1 Cast iron Casing material 2 Ductile iron X Special 7 Silicon bronze ASTM B584 Impeller...

Page 7: ...itable for protection during shipment and during covered storage at a job site for a short period between installation and startup The preservatives applied at the factory have an effective life of tw...

Page 8: ...ommend installing the base plate without the pump Position the foundation and the foundation bolts so that pump inlet and outlet flanges align with the outlet pipes Related information 4 4 2 Foundatio...

Page 9: ...uate headroom must be provided to accommodate the pump to be handled plus the rigging WARNING Overhead load Death or serious personal injury Only lift the entire pump assembly with the lifting lugs pr...

Page 10: ...pockets drill small vent holes through the base surface 5 Level off the grout to be flush with the top of the dam 6 Allow the grout to cure usually 48 to 72 hours before tightening the foundation bol...

Page 11: ...pply before you start any work on the product Make sure that the power supply cannot be switched on accidentally Locate the electrical conduit and boxes so as to avoid obstruction of the pump Check sp...

Page 12: ...otherwise specified by the customer Carefully check the packing allowing a slight leakage for lubrication Do not force the packing into a leak proof position as this will create excessive friction and...

Page 13: ...ates freely 3 Check that the voltage and frequency on the motor nameplate match the current supply 4 Be sure the motor is wired for correct voltage 5 Check that all thermal overload relays are of the...

Page 14: ...e pump WARNING Electric shock Death or serious personal injury Switch off the power supply before you start any work on the product Starting the motor during pump removal could damage pump and may cau...

Page 15: ...st be replaced 1 Measure the outer diameter OD of the impeller wear surface or wear ring 8 and the inner diameter ID of the volute wear ring 7 2 Compute the diametrical clearance ID minus OD and compa...

Page 16: ...depending on the severity of the environment For international destinations this will vary depending on the seaworthiness of the product s export packaging Related information 3 5 Handling and storin...

Page 17: ...attention to the condition of the shaft seals or the packing and O rings Related information 7 1 Storage 7 1 5 Accessories storage Store accessories according to the manufacturer s instructions Relat...

Page 18: ...between sleeve and shaft Check gaskets The suction head is insufficient The suction line is drawing air Tighten the line connections The suction lift is too high or there is insufficient NPSH Reduce...

Page 19: ...r starting Joints are leaking Tighten the joints Tighten the packing Check o ring between sleeve and shaft Replace the gaskets The suction lift is too high or there is insufficient NPSH Reduce the suc...

Page 20: ...rew impeller 83 Stuffing box 27 Ring stuffing box cover 119 O ring 9 Disposing of the product This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or privat...

Reviews: