background image

1

2022-07-06    #:180-9147-1

ENG

Installation Guideline

 

For XHB554

Summary of Contents for XHB554

Page 1: ...1 2022 07 06 180 9147 1 ENG Installation Guideline For XHB554 ...

Page 2: ... be located near overhead electrical lines or any electrical circuits If an outside antenna is connected to the receiver confirm that the antenna system is grounded to protect against voltage surges and built up static charges Section 810 of the National Electric Code ANSI NFPA No 70 1984 provides information with respect to proper grounding for the mast and supporting structure grounding of the l...

Page 3: ...ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications however there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television receptio...

Page 4: ...or near moving objects constantly vibrating equipment or uneven surfaces Do not leave any fire source such as candles close to or on the product Do not operate the product if it has been dropped or struck Severe physical impact to the product may cause components to fall out of place within and break Do not bend or twist electrical cords electrical plugs cables or wires with excessive force Do not...

Page 5: ...n any third party enclosure without written authorization from Peerless AV are not covered by the Peerless AV Limited Warranty nor any extended warranty When installing in an enclosure or recessed cavity the internal temperatures of those locations must not exceed the maximum operating temperatures as listed above The product is to be secured to building before operation Product must be carried an...

Page 6: ... additional 30 C over ambient temperature The end user installer must note the potential for temperature increase based on high thermal solar load which needs to be addressed with additional cooling measures Please contact Peerless AV for design consultation in such cases If installed in extremely cold locations the end user installer must note the potential for temperature decrease based on envir...

Page 7: ...her temperature rise Peerless AV Engineering should be consulted in these situations Peerless AV Engineering must be consulted before placing the display into any enclosure not developed by Peerless AV Peerless AV Engineering management must approve this installation solution to support the native warranty of the display 600 60 5 4 54 6 700 60 6 4 53 6 800 60 7 6 52 4 900 60 10 2 49 8 50 52 54 56 ...

Page 8: ...8 2022 07 06 180 9147 1 This page intentionally left blank ...

Page 9: ...ape orientation the sensor window will be on the top left of the display When in portrait orientation the sensor window will be on the top right of the display Portrait Portrait Landscape Landscape 90 90 SENSOR WINDOW LOCATION Portrait Landscape Display Orientation Do not block the sensor window If window is blocked consult with Peerless AV for proper IR extender included with product and ALS exte...

Page 10: ... supports the weight of the display When mounting a display outdoors use proper environmentally rated mounts to ensure longevity in harsh environments Examine the chart below to determine the mounting specifications for your display B F H D Display Size A B C D E F G H I 55 15 75 400mm 15 75 400mm 17 16 436mm 6 74 171mm 3 92 100mm 7 87 200mm 23 62 600mm 23 62 600mm 33 46 850mm SIDE VIEW A G I C E ...

Page 11: ...tern Four M8 x 20mm screws and mount sold separately Maximum 45 in lb 5 N M Do not overtighten Removing Handles Optional CAUTION Do not remove the screws above or below the handles Failure to follow these instructions can result in the product being damaged or destroyed voiding the warranty Do not remove 5mm ...

Page 12: ... use either 400mm x 400mm VESA mounting patterns on the raised portion of the rear surface Note this may limit access to removable input cover Installers can also use either a 600 x 600mm mounting pattern or the 600 x 850mm perimeter mounting locations Four M8 x 35mm screws and mount sold separately Do not overtighten Maximum 45 in lb 5 N M ...

Page 13: ...7 06 180 9147 1 For portrait or landscape oriented displays the maximum downward tilt is 15 For other orientations consult Peerless AV 2 50mm Minimum 2 50mm Minimum 15 MAX LANDSCAPE PORTRAIT 15 MAX Maximum Tilt ...

Page 14: ...2 Y1 Y2 W Consult Peerless AV for minimum spacing when installing two or more adjacent displays Note These are minimum requirements Internal heat sources due to additional equipment external heat sources and high solar loads may require additional spacing and airflow Please consult Peerless AV for additional guidance ...

Page 15: ...inimum spacing when installing two or more adjacent displays Note These are minimum requirements Internal heat sources due to additional equipment external heat sources and high solar loads may require additional spacing and airflow Please consult Peerless AV for additional guidance Minimum Airflow Spacing ...

Page 16: ... AV when installing two or more adjacent displays Note These are minimum requirements Internal heat sources due to additional equipment external heat sources and high solar loads may require additional spacing and airflow Please consult Peerless AV for additional guidance Minimum Airflow for one Display 100 ft min Minimum Airflow for two Displays 175 ft min ...

Page 17: ...um requirements Internal heat sources due to additional equipment external heat sources and high solar loads may require additional spacing and airflow Please consult Peerless AV for additional guidance CAUTION Do not impede airflow by blocking ventilation holes Preferred Minimum Airflow for one Display 100 ft min Minimum Airflow for two Displays 175 ft min ...

Page 18: ...18 2022 07 06 180 9147 1 drip service loop drip service loop Use only high quality shielded grounded cables drip service loop media device media device media device Routing Cables in the Display ...

Page 19: ...ing 3mm allen wrench to secure Ensure the rear cover plate is fully compressed to the back of the display Ensure cord bend radius does not exceed limits set by the manufacturer Ensure cords are seated properly in the cable channels to avoid potential damage to cords when rear cover plate is installed Do not remove lanyard that connects the rear cover plate to the display Ensure cables exiting inpu...

Page 20: ...mild detergent Clean cloth Aerosol Abrasive cleaner Cleaning the Screen Do not rub or strike the screen with anything hard as this may scratch mark or even damage the screen permanently Unplug the power cord before cleaning the screen Do not spray water on the display in excess of 100kPa 14 5 PSI ...

Page 21: ...21 2022 07 06 180 9147 1 This page intentionally left blank ...

Page 22: ...22 2022 07 06 180 9147 1 This page intentionally left blank ...

Page 23: ...23 2022 07 06 180 9147 1 This page intentionally left blank ...

Page 24: ...al Escobedo General Escobedo N L México 66062 Servicio al Cliente 01 800 849 65 77 www peerless av com 2022 Peerless Industries Inc Peerless AV 2300 White Oak Circle Aurora IL 60502 Email tech peerlessmounts com Ph 800 865 2112 Fax 800 359 6500 www peerless av com 2022 Peerless Industries Inc www peerless av com warranty Warranty Garantía Garantie Garantie Garantie Garanzia Záruka Záruka Garantia ...

Reviews: