background image

Maximum Load Capacity: 

200 lb (90.7 kg)

Model: DS509

Installation and Assembly

2300 White Oak Circle  •  Aurora, IL 60502  •  (800) 865-2112  •  Fax: (800) 359-6500  •  www.peerlessmounts.com

ISSUED: 04-06-09  SHEET #:125-9059-3   07-11-11   

 

os

pd

For OSHPD installations, 
please contact Peerless 
Customer Service for a 
copy of the OPA.

Summary of Contents for DS509

Page 1: ...Installation and Assembly 2300 White Oak Circle Aurora IL 60502 800 865 2112 Fax 800 359 6500 www peerlessmounts com ISSUED 04 06 09 SHEET 125 9059 3 07 11 11 os pd For OSHPD installations please contact Peerless Customer Service for a copy of the OPA ...

Page 2: ... Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not overtighten Overtightening can damage the items greatly reducing their holding power This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury This p...

Page 3: ... wood screw 4 5S1 015 C03 D concrete anchor 4 590 0097 E M8 x 15 mm socket pin screw 4 520 1068 F M4 x 12 mm phillips screw 4 504 9013 G M5 x 12 mm phillips screw 4 520 1027 H M6 x 12 mm phillips screw 4 520 1128 I M10 x 15 mm socket screw 4 520 9262 J 8 SAE flat washer 4 540 1001 K 3 4 x 3 16 x 10 adhesive strip 2 570 1029 L cable tie 4 560 9711 M 4 mm allen wrench 1 560 9646 N 1 4 20 x 2 5 phill...

Page 4: ...level secure it using four 14 x 2 5 wood screws C as shown Skip to step 2 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess o...

Page 5: ...0 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components WARNING 1 3 2 Tighten screws so that wall plate is firmly attached but do not overtighten Overtightening can damage screws greatly reducing their holding power Never tighten in excess of 80...

Page 6: ...e 1 3 Loosely fasten wall plate to wall using four 1 4 20 x 2 1 2 screws N and six 1 4 washers P as shown in figure 1 4 Level hold and then tighten all screws 1 Drywall must be 1 2 or thicker and metal stud must be 24 gauge or thicker Make sure that the wall will safely support the combined load of the equipment and all attached hardware and components Make sure that togglers are anchored into the...

Page 7: ...ding on size of CPU as shown in figure 2 2 2 NOTE Safety belt may need to be loosened to attach CPU to wall plate A Press CPU against adhesive strips on wall plate and tightly secure safety belt against CPU 3 Placement of adhesive strips K for larger CPU s Placement of adhesive strips K for smaller CPU s CPU A K fig 2 2 A SAFETY STRAP fig 2 1 Placement of Adhesive Strips Attach CPU to Wall Plate ...

Page 8: ...mounting patterns Hand thread screws F G or H through washers J or P and adapter plate B into screen as shown in figure 4 1 Screw must make at least three full turns into the mounting hole and fit snug into place Securely tighten screws If screws don t get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured damage may occur to screen or produ...

Page 9: ...op two M8 x 15 mm screws E 1 4 turn and temporarily remove bottom two M8 x 15 mm screws E on adapter plate A as shown in figure 6 1 Swing screen forward and swing support brackets downward into adapter plate B to brace screen in open position as shown in figure 6 2 6 Attaching Adapter Plate to Wall Plate Accessing CPU BOTH SIDES fig 5 1 fig 5 2 E LOOSEN 1 4 TURN ON BOTH SIDES E SUPPORT BRACKETS BO...