peerless-AV DS-S555-3X2 Manual Download Page 1

1

2014-07-28    #:009-9088-4    (2018-03-09)

ENG

DS-S555-3X2

46" - 55"  

(117 - 140 cm)

600 lb 

(272 kg)

MAX

Summary of Contents for DS-S555-3X2

Page 1: ...1 2014 07 28 009 9088 4 2018 03 09 ENG DS S555 3X2 46 55 117 140 cm 600 lb 272 kg MAX ...

Page 2: ...njury Displays must be removed before moving cart Not recommended for use in areas with heavy traffic This product is intended for indoor use only Use of this product outdoors could lead to product failure or personal injury Screws must be tightly secured Do not overtighten screws or damage can occur and product may fail Never exceed the Maximum Load Capacity Be careful not to pinch fingers when o...

Page 3: ...rd bracket 4 146 T1321 L knob 4 560 1160 M cross support 2 146 T1904 N plate connections 4 145 T1821 O M8 x 16mm socket button screw 68 520 9527 P M8 square nut 32 530 1066 Q cover clip 8 590 0317 R M5 x 10mm type f socket pin screw 14 520 1164 S 1 4 power bit 1 560 0263 T 5mm allen wrench 1 560 9640 U nylon shoulder washer 24 590 2233 V M6 x 12mm socket pin screw 24 520 1050 W 4mm allen wrench 1 ...

Page 4: ...er cover J 2 dual cross support O 68 M8 x 16mm P 32 M8 square nut Q 8 cover clip R 14 M5 x 10mm S 1 1 4 power bit T 1 5mm allen wrench U 24 nylon shoulder washer V 24 M6 x 12mm N 4 plate connections I 1 computer shelf rawl bolt Y 8 M6 x 35mm X 8 K 4 cord bracket L 4 knob Z 4 M8 x 20mm ...

Page 5: ...5 2014 07 28 009 9088 4 2018 03 09 1 x2 X 4 A B ...

Page 6: ...6 2014 07 28 009 9088 4 2018 03 09 DISPLAY HEIGHT TIGHTEN CONNECTING HARDWARE 2 1 2 2 O 6 P 4 G 1 8 3mm 1 8 3mm x4 T T ...

Page 7: ...7 2014 07 28 009 9088 4 2018 03 09 3 1 x2 x2 Q 4 C 3 2 K 2 L 2 TOP VIEW TIGHTEN CONNECTING HARDWARE K L ...

Page 8: ...20 cm hebben en een druksterkte van ten minste 2000 psi Gebruik nooit expansie ankers voor beton bij installatie op een betonnen plafond bedekt met gips gipsplaat of ander afwerkingsmateriaal ITL In sede d installazione dei sostegni Peerless su un soffitto in calcestruzzo solido il soffitto deve avere uno spessore minimo di 20 cm con una resistenza alla compressione di almeno 2000 psi 140 kg cm2 N...

Page 9: ... 8 4 1 Align base Mark mounting holes ENG 4 2 Drill mounting holes into supporting surface 3 76mm minimum depth required ENG 3 8 10mm 4 3 Align base Install using concrete anchors provided ENG 3 8 10mm 55 00 1397mm ENG Maximum 35 ft lb 47 N M 55 00 1397mm ...

Page 10: ...10 2014 07 28 009 9088 4 2018 03 09 5 1 5 2 5 3 J M O 4 O 4 P 4 P 2 Z 2 N 2 x2 x2 x2 T T T ...

Page 11: ...11 2014 07 28 009 9088 4 2018 03 09 6 1 Cross supports must center on columns T Tighten ENG Tighten ENG ...

Page 12: ...12 2014 07 28 009 9088 4 2018 03 09 6 2 Cross supports must center on columns Tighten ENG Tighten ENG T ...

Page 13: ...13 2014 07 28 009 9088 4 2018 03 09 7 F F 2 O 2 O 4 P 2 P 4 T ...

Page 14: ...14 2014 07 28 009 9088 4 2018 03 09 W X X 8 1 E D 8 2 Center adapter brackets vertically on back of screen ENG E D x3 U V O OR x6 x6 T ...

Page 15: ...g displays to bottom row first Secure pin in locked position Must hang displays on top row second Secure pin in locked position 9 1 9 2 9 3 OPTIONAL Insert M5 x 10mm type F socket pin screws to lock latches W LOCKED POSITION LOCKED POSITION R x12 ...

Page 16: ...16 2014 07 28 009 9088 4 2018 03 09 IN TILT BACKWARD OUT TILT RIGHT TILT FORWARD TILT LEFT SIDE SIDE SIDE TOP SIDE TOP Display Adjustment UP DOWN ROTATE LEFT ROTATE RIGHT ...

Page 17: ...17 2014 07 28 009 9088 4 2018 03 09 10 I ...

Page 18: ...18 2014 07 28 009 9088 4 2018 03 09 I R 2 I H TIGHTEN CONNECTING HARDWARE 11 1 11 2 1 8 3mm W W ...

Page 19: ...19 2014 07 28 009 9088 4 2018 03 09 12 Route cables through cord brackets K K ...

Page 20: ...allow limitations on how long a implied warranty lasts so the above limitation may not apply to you This warranty does not cover damage caused by a service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or w...

Reviews: