Peco WavePRO R2500 Installation Manual Download Page 1

Benefi ts:

•  Reduced installation time
•  Reduced wiring costs
•  Energy cost savings

•  Scalability of network
• Flexibility in fl oor planning
•  Ideal for building renovation

PECO WavePRO

 Wireless System 

INSTALLATION GUIDE: 
T2500 THERMOSTAT AND R2500 RECEIVER

Wireless control for up to 3-HEAT/ 2-COOL 
heat pump and conventional systems 
(gas,oil,electric).  

The Peco WavePRO Wireless System

The PECO WavePRO

 Wireless System is a wireless thermostat transmitter and 

receiver. It is designed for use with conventional (gas, oil, electric) or heat-pump 
systems. It can support up 2-HEAT/ 2-COOL confi guration on conventional systems 
and up to 3-HEAT/ 2-COOL confi gurations of heat pump systems. The PECO 
WavePRO Wireless System is comprised of the wireless T2500 Thermostat paired with 
the wireless R2500 Receiver. 
The T2500 Thermostat may be powered by battery, 24 VAC, or by both 
(recommended). The system may be programmed for 7-day individual, 5/2-day, 
5/1/1-day, or 7-day identical programmable operation, with four time periods per day. 
The R2500 Receiver is powered by 24 VAC only and is wired directly to the HVAC 
equipment it controls. 

Summary of Contents for WavePRO R2500

Page 1: ...er It is designed for use with conventional gas oil electric or heat pump systems It can support up 2 HEAT 2 COOL configuration on conventional systems and up to 3 HEAT 2 COOL configurations of heat p...

Page 2: ...talled this product will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by PECO You must review your application and national and l...

Page 3: ...on checklist WavePRO Wireless System T2500 and R2500 mounting considerations Locate the T2500 and R2500 within 100 ft 30 m of one another Avoid locating devices within a metal enclosure or between lar...

Page 4: ...INSTALLATION TIPS WARNING Disconnect power before beginning installation Mount the R2500 on a wall near the HVAC equipment Choose indoor mounting locations free from obstructions CAUTION Use copper wi...

Page 5: ...ws evenly 5 Connect equipment wire to the R2500 terminals a Match equipment wire to the R2500 terminals referencing the appropriate wiring examples below see R2500 wiring examples section of these ins...

Page 6: ...pressor contactor Y First stage cool relay contactor Aux Auxiliary heat relay contactor Y2 Second stage cool relay contactor G Fan relay G Fan relay E Emergency heat relay contactor Terminal Designati...

Page 7: ...Function 1 C 24VAC 2 2 R 24VAC 1 3 Y1 Compressor 1 4 Y2 5 O B Reversing valve 6 AU Emergency 7 A Economizer 8 G Fan Note If remote probe is used please refer to the Terminal Designations Overview p 6...

Page 8: ...4VAC 1 3 Y1 Cooling stage 1 4 Y2 5 W1 Heating stage 1 6 W2 Heating stage 2 7 A Economizer 8 G Fan Note If remote probe is used please refer to the Terminal Designations Overview p w 6 System Type 9 1H...

Page 9: ...operated on 24 VAC power with battery backup MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact your local...

Page 10: ...8 Attach wires to the T2500 Thermostat backplate 1 Using a small flathead screwdriver loosen the screws on the terminal block located on the backplate to allow the wires to be inserted easily 2 Strip...

Page 11: ...ore information on using thermostat s buttons and features refer to the WavePRO Wireless Programmable T2500 Thermostat R2500 Receiver Operating Manual 5 Establish a wireless connection Perform wireles...

Page 12: ...ing the R2500 was found but pairing process is not yet complete T2500 Display will show the room temperature e Wait for up to 10 minutes to allow completion of pairing process Do not press buttons dur...

Page 13: ...sked questions troubleshooting If replacing either the T2500 or the R2500 follow these instructions A brief connection process must be performed that erases all previously paired devices from the R250...

Page 14: ...s and then depress the CONNECT button for less than five seconds this resets R2500 to its initial state Temperature Display F C Select Fahrenheit F or Celsius C Menu 1 0 C 1 F Default 1 Fahrenheit Opt...

Page 15: ...Menu 12 0 OFF AUTO 1 OFF HEAT COOL AUTO 2 OFF HEAT COOL 3 AUTO HEAT COOL Default 1 Options 0 3 Selection _________ Front Panel Setback Mode Enable Allows user to select setback as a system mode Menu 1...

Page 16: ...me for Heat and Cool Set the minimum off time for heat and cool output Menu 40 Default 4 min Options 1 10 minutes Selection _________ Temp Source Allows use of remote sensor option on R2500 Menu 42 0...

Page 17: ...1 Cool multistage conventional 9 1 Heat 2 Cool multistage conventional 10 2 Heat 2 Cool heat pump no Aux heat 11 3 Heat 2 Cool heat pump with Aux heat Default 0 Options 0 11 Selection _________ Fan C...

Page 18: ...election _________ Economizer Control Menu 60 0 Unused 1 Economizer 2 Time of Day TOD Default 0 Options 0 2 Selection _________ Revision Displays current revision information for service technician no...

Page 19: ...is broken between R2500 and T2500 for more than 10 minutes Thermostat LED light will shut off on the R2500 and will shut off all outputs 1 Verify that both R2500 and T2500 have power 2 If the Thermos...

Page 20: ...ion is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired...