Peco WavePRO K2500-001 Operating Manual Download Page 1

1

WavePRO Wireless Programmable 
T2500 Thermostat & R2500 Receiver

 

OPERATING 
MANUAL 

Model K2500-001

Summary of Contents for WavePRO K2500-001

Page 1: ...1 WavePRO Wireless Programmable T2500 Thermostat R2500 Receiver OPERATING MANUAL Model K2500 001...

Page 2: ...The PECO WavePRO Wireless System is comprised of the T2500 wireless thermostat paired with the R2500 wireless receiver This operating manual contains important information on operating the T2500 ther...

Page 3: ...50 60 Hz Wireless Type 902 to 928 MHz Band Frequency Hopping Spread Spectrum FHSS Wireless Range 100 feet 30 48 meters typical reliable range in open air Operation Temperature 0 to 120 F 17 to 48 C Sh...

Page 4: ...nt panel display reference T2500 thermostat 6 Button operation 7 The T2500 display 10 The T2500 display menus 11 Set the time and day 14 Selecting the Fahrenheit or Celsius temperature 15 Programming...

Page 5: ...thermostat operating voltage To avoid potential fire and or explosion do not use in potentially flammable or explosive atmospheres This product when installed will be part of an engineered system who...

Page 6: ...rmostat Display and buttons FRONT PANEL DISPLAY REFERENCE T2500 THERMOSTAT SETBACK MTUWTHFSASU DFLTSLEEP OFF HEAT COOL AUTO FAN Auto ON SET HOLD COPY Aux SYSTEM button 1 Display 2 FAN button 4 UP and...

Page 7: ...e SYS modes are HEAT Indicates the system is in heating mode COOL Indicates the system is in cooling mode AUTO Indicates the system will automatically changeover between heating and cooling modes as t...

Page 8: ...PROG program button is used to program the T2500 Press PROG button once to light up five program mode options described below Press or buttons to scroll through the options As you scroll the option be...

Page 9: ...f days see Programming the T2500 HOLD Puts the thermostat in Temporary or Permanent Hold mode Overrides your programmed settings but does not lose them see Overriding the program Up and Down Button Op...

Page 10: ...play Programming Commands Program Override Commands Temperature Display Time Period Indicators Service Indicator Time Day Display Fan Operation Indicators THE T2500 DISPLAY 1 2 3 4 5 6 7 8 SETBACK MTU...

Page 11: ...mode To appear SETBACK must be selected in Advanced configuration See the PECO WavePRO Wireless System Installation Guide Temperature Display Default display Digits display the current room temperatur...

Page 12: ...owing you to copy all of an individual day s settings to another day or group of day DFLT Restores the thermostat to the factory program Time Period Indicators WAKE DAY EVE and SLEEP are the names giv...

Page 13: ...ntained indefinitely or until the Permanent Hold is turned off HOLD OFF Turns the Permanent Hold off and resumes programmed settings Service Indicator The wrench symbol will flash during wireless pair...

Page 14: ...gh 24Hr AM PM options 24Hr sets your thermostat to a 24 hour clock AM and PM sets your thermostat to a 12 hour clock To select press PROG once 4 Press or to scroll to the current hour To select press...

Page 15: ...roll until BOTH F C are flashing 3 Press PROG once to enter the temperature menu for F C Note Either F or C will flash as an option 4 Press or to ito scroll to select the flashing option as desired F...

Page 16: ...d to function with the ENERGY STAR settings Factory Program The T2500 is preprogrammed with seven days of the week Time Period Start Time Heat Setpoint Temperature Cool Setpoint Temperature Wake 6 00...

Page 17: ...or for all seven days as identical Follow this step by step procedure 1 Press PROG once 2 Press or to scroll until SET is flashing 3 Press PROG once to select a menu option 4 Press or to scroll to th...

Page 18: ...onday TU Tuesday W Wednesday TH Thursday F Friday SA Saturday and SU Sunday You must program four periods for each day 7 Day Identical Programming MTUWTHFSASU flashes as a block Select MTUWTHFSASU to...

Page 19: ...gh the four time periods WAKE DAY EVE and SLEEP Select the time period to be programmed and press PROG once 8 Press or to scroll to the desired starting hour Press PROG once 9 Press or to scroll to th...

Page 20: ...4 Press or to scroll to the individual day from which you want to copy 5 Press PROG once COPY will begin flashing Settings for flashing day s are now copied 6 Press or to find the day s to which you...

Page 21: ...s PROG once 5 Press or to scroll hours to 8 To select press PROG once 6 Press or to scroll minutes to 30 To select press PROG once 7 User wants to keep same Heat Setpoint Temperature Press PROG once 8...

Page 22: ...ettings but does not lose them 1 Press PROG once 2 Press or to scroll until HOLD is flashing To select press PROG once 3 Press or to scroll through options DAYS allows you to specify 0 99 days hold HR...

Page 23: ...w on hold until you manually turn off the hold Turning off a Hold 1 Press PROG once 2 Press or to scroll until HOLD is flashing To select press PROG once 3 Press or to scroll to OFF To select press PR...

Page 24: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to rad...