background image

9

IEC MAINS CONNECTOR

This is a standard IEC power connector. An AC mains cord having the appropriate AC plug and ratings for the intended 

operating voltage is included in the carton.

U.S. DOMESTIC AC MAINS CORD

The mains cord supplied with the unit is a heavy-duty, three-conductor type with a conventional 120 VAC plug with ground pin. 

It should be connected to an independent circuit capable of continuously supporting at least 15 amps. This is particularly critical 

for sustained high-power applications. If the outlet used does not have a ground pin, a suitable grounding adapter should be 

used and the third wire grounded properly.

Never break off the ground pin on any equipment. It is provided for your safety.

The use of extension cords should be avoided but, if necessary, always use a three-wire type with at least a #14 AWG 

wire size. The use of lighter wire will severely limit the power capability of this amplifier. Always use a qualified 

electrician to install any new electrical equipment. To prevent the risk of shock or fire hazard, always be sure that the amplifier 

and all associated equipment is properly grounded.

NOTE: FOR UK ONLY

If the colors of the wires in the mains lead of this unit do not correspond with the colored markings identifying the terminals in 

your plug, proceed as follows: (1) The wire that is colored green and yellow must be connected to the terminal that is marked 

by the letter E, the earth symbol, colored green, or colored green and yellow. (2) The wire that is colored blue must be 

connected to the terminal that is marked with the letter N or the color black. (3) The wire that is colored brown must be 

connected to the terminal that is marked with the letter L or the color red.

LINE VOLTAGE SELECTOR SWITCH

The PV series power transformer is designed with two primaries that can be placed in series or parallel by means of the line 

voltage selector switch. It is accessible by loosening one screw and rotating the transparent guard out of the way. Please be 
sure this is set to the proper voltage for your area before turning the amplifier on for the first time.

BINDING POST OUTPUTS

 

Shockproof binding post speaker outputs are provided on the PV® amplifier. For each channel, the outputs are in parallel and 

the speaker connection cables can be terminated with banana plugs or stripped wires for use in the binding post terminals, or 

can be connected using the twist lock outputs (11). For sustained high-power applications, either outputs can be used; 

however, exercise care to assure the correct speaker polarity. The red binding posts are the signal outputs from each channel, 

and the black binding posts are chassis ground. The red binding post should be connected to the positive inputs of the 

associated loudspeakers. For BRIDGE mode operation, only the red binding posts are used, and the loudspeaker load is 

connected between the two red posts, with CH A having positive polarity and CH B having negative  polarity.

WARNING. 

Regardless of what connections are used, the minimum parallel speaker load should always be limited to 

2 Ohms per channel, or 4 Ohms when in BRIDGE mode. Operation at loads of 4 Ohms per channel, or 8 Ohms 

BRIDGE mode, is more desirable for sustained operation applications because the amplifier will run much cooler with 

this load. Operation above 4 Ohms per channel and even open-circuit conditions can always be considered safe, but sustained 

operation at loads below 2 Ohms could result in temporary amplifier shut down due to the thermal limit circuitry.

TWIST LOCK OUTPUTS

 

PV® amplifiers utilize three 4-conductor twist lock connectors, one for each channel and one for BRIDGE mode. Please refer 

to the BRIDGE MODE section of this manual before attempting to use this mode. For each channel twist lock, the same 

impedance rules apply as with the binding posts. Internally, all the twist locks are wired in the “high current” configuration, with 

13

INPUTS

CHANNEL 

A

CHANNEL 

A

CHANNEL 

B

CHANNEL 

B

LINE OUTS

BRIDGE

BRIDGE

SPEAKER OUTPUTS

MADE IN CHINA

230V

T 15AL

250V

115V

MOUNT IN RACK ONLY

INSTALLER SUR SUPPORT
DE MONTAGE SEULEMENT

BRIDGE

+

+

+

_

_

_

DDT

TM

STEREO

BRIDGE

A

B

+

-

+

-

40 Hz

GND

40 Hz

150 Hz

X-OVER

150 Hz

X-OVER

HIGH

OUT

LOW

OUT

HIGH

OUT

LOW

OUT

THRU

THRU

ENABLE
DEFEAT

7

Rear Panel

8

8

9

10

10

11

13

12

14

18

19

16

15

17

10

20

9

11

Summary of Contents for PV 1

Page 1: ...THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR ...

Page 2: ...RS phone jack connector THRU LOW out and HIGH out TRS jacks and activation switches for the LOW CUT filter and crossover 150 Hz XOVER Channel output sections feature dual shock proof binding posts and four conductor twist lock connectors An additional four conductor twist lock connector allows BRIDGE mode output UNPACKING Inspect the amplifier during unpacking If any damage is found notify your de...

Page 3: ...it is helpful to leave 1 RU open above and below the amplifier to prevent heat buildup from adjacent units POWER SWITCH This heavy duty rocker type switch turns on the mains power to the amplifier When the mains power is applied there is a delay in activation of the unit This reduces eliminates the turn on transients associated with the system equipment connected to the amplifier and protects loud...

Page 4: ...ea before turning the amplifier on for the first time BINDING POST OUTPUTS Shockproof binding post speaker outputs are provided on the PV amplifier For each channel the outputs are in parallel and the speaker connection cables can be terminated with banana plugs or stripped wires for use in the binding post terminals or can be connected using the twist lock outputs 11 For sustained high power appl...

Page 5: ...ound It is important to realize that the XLR 1 4 jack and barrier strip inputs are all in parallel therefore a balanced input to the associated channel can be accomplished using a male XLR a 3 conductor phone jack or bare wires connected to the barrier strip As an alternative the 1 4 input can also be used with a regular tip sleeve 2 conductor type plug commonly found on single conductor shielded ...

Page 6: ...y steps to provide adequate cooling The PV Series should never be operated in a fully enclosed cabinet BRIDGE MODE When a 2 channel amplifier is operated in the Bridge mode it is converted into a single channel unit with a power rating equal to the sum of the power rating for each channel at a load of twice that of the single channel rating For example the PV 2 is rated at 750 Watts RMS per channe...

Page 7: ... to 35 kHz DAMPING FACTOR Typical value Stereo mode both channels driven 8 Ohms 20 Hz 2 kHz 250 1 POWER CONSUMPTION Stereo mode both channels driven 1 8 rated output power 4 Ohms 450W 680W 600W TOPOLOGY Class AB Class AB Class G WEIGHT 40 lbs 18 2 kg 45 lbs 20 5 kg 49 lbs 22 3 kg FEATURE SET All Models indicates each channel DDT COMPRESSION Automatic switchable with LED indicator COOLING SYSTEM Tw...

Page 8: ...13 T 9 1 2 T 9 1 2 ...

Page 9: ...14 ...

Page 10: ...ed only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 ...

Reviews: