P550c Operation Manual
4 System assembly
69
MK3 system connectors are not compatible with MK1 and MK2 sockets. Contact Pearpoint or your local
distributor for the latest compatibility options.
Caution!
The external connectors must be properly sealed by the blanking caps provided, or by
using the correct leads to prevent water damage. Under no circumstances are these connectors
to be left un-blanked.
Note
:
The Powered drum is capable of winding in deployed cable. When retrieving the cable, the drum
will rewind slightly faster than the crawler is reversing, in order to keep tension on the cable. This is
normal operation.
4.3 Command module
Mounting
Mount the command module to the drums using the support column or stand. The height can be
adjusted on the powered drum support column.
Power, data and video
When using the manual or powered drum, a single link cable supplies the command module with power,
data and video. The link cable socket is located on the back of the controller.