-0-
PeakTech
1636
Bedienungsanleitung/
Operation Manual
AC Leckstromzange /
AC Leakage current clamp meter
Page 1: ... 0 PeakTech 1636 Bedienungsanleitung Operation Manual AC Leckstromzange AC Leakage current clamp meter ...
Page 2: ...ahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische Änderungen des Gerätes welche dem Fortschritt dienen vorbehalten Hiermit bestätigen wir dass alle Geräte die in unseren Unterlagen genannten Spezifikationen erfüllen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech ...
Page 3: ...urrent use counter To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not subject the equipment to direct sunlight extreme temperatures extreme humidity or dampness Do not ope...
Page 4: ... 13 3 Controls 1 Clamp for current measurement 2 Lever to open the Current clamp 3 Function switch 4 DATA Hold display backlight 5 Max value function 6 LCD display 1 2 3 4 5 6 ...
Page 5: ...ithout separate measuring lines which have to be connected to the device 1 Set the Switch to the desired measuring range for the respective current measurement 2 Insert the lead to be measured into the current clamp opening by operating the lever to open the clamp 3 After closing the current clamp meter the measured value is shown on the LCD display Observe the correct procedure during the measure...
Page 6: ...e background lighting is switched on the Hold function is also activated but you can switch it off again by briefly pressing the Hold button again The display lighting switches off after approx 15 seconds by itself It is also possible to switch the lighting off manually by pressing the Hold button again for approx 2 seconds 4 4 Max function To hold the maximum measured value in the display press t...
Page 7: ... battery symbol appears on the display To change the batteries follow the following steps 1 Set the switch position of the device to OFF 2 Unscrew the battery compartment on the back of the clamp meter and remove the empty batteries 3 Insert new AAA 1 5V batteries into the battery compartment 4 Pay attention to the correct polarity of the batteries when inserting them 5 Close the battery compartme...
Page 8: ...wer off After approx 15 minutes Operating temperature 0 C up to 30 C 31 F up to 86 F 90 RH 30 C up to 40 C 86 F up to 104 F 75 RH 40 C up to 50 C 104 F up to 122 F 45 RH Display 3 digit 1999 counts LCD Sampling rate 2 readings seconds nominal Current clamp diameter Approx 3 cm Power supply 2 x 1 5V AAA batteries Dimensions 182 x 61 x 34mm H x W x D ...
Page 9: ... of old batteries at a council collection point or return them to a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps Contaminated batteries shall be marked with a symbol consisting of a crosse...