3.1
Configuration LIN Transceiver
According the highest bit rate that is used on the LIN bus, you can
select between two LIN transceivers:
max. 10,4 kbit/s: TJA1028T/5V0/10 (Low-speed)
max. 20 kbit/s: TJA1028T/5V0/20 (High-speed, default setting)
The transceiver with the /10 ending generates less steep slopes,
thus the electromagnetic compatibility is enhanced.
Figure 6: Position of the jumper blocks JP3 and JP7
Transceiver
Jumper setting
JP3 and JP7
Comment
Low-speed (/10)
1-2
High-speed (/20)
2-3
Default setting at delivery
Tipp:
Both PLIN-LWL modules being connected with each other