PCAN-USB Pro – User Manual
10
3
Both D-Sub connectors on the PCAN-USB Pro adapter are each
used for connecting one CAN and one LIN bus. The pin assignment
is identical for both D-Sub connectors.
Note:
Since the application possibilities of the PCAN-USB Pro
adapter are various, special cable adapters for connecting the
CAN and LIN busses are not provided. Therefore you need a
9-pin D-Sub female connector for your appliances to be
connected individually.
Two High-speed CAN busses (ISO 11898-2) can be connected, one
to each D-Sub connector. The pin assignment for CAN corresponds
to the specification CiA® 102.
Figure 1: CAN pin assignment of the D-Sub connector
Each CAN connection separately has a
galvanic isolation
up to
500 V against USB and LIN.
Tip:
You can connect a CAN bus with a different transmission
standard via a bus converter. PEAK-System offers different bus
converter modules (e.g. PCAN-TJA1054 for a Low-speed CAN
bus according to ISO 11898-3).