3.1
Alternative CAN Transceiver Modules
An alternative CAN transceiver module can be used for each of the
four CAN connections. The
PCAN-Transceiver TJA1041
is preinstalled
by default. The following alternative modules are supported:
Order
Number
Name
Transmission
Standard
Bit Rate
Wake-
up
Galvanic
Isolation
IPEH-001001
Default
PCAN-Transceiver
TJA1041
High-Speed-CAN
ISO 11898-2
40 kbit/s to
1 Mbit/s
yes no
IPEH-001002 PCAN-Transceiver
PCA82C251
High-Speed-CAN
ISO 11898-2
5 kbit/s to
1 Mbit/s
no no
IPEH-001003 PCAN-Transceiver
MAX3057-ISO
High-Speed-CAN
ISO 11898-2
5 kbit/s to
1 Mbit/s
no yes
IPEH-001004
PCAN-Transceiver
TH8056
Single-Wire-CAN
SAE J2411
1.3 kbit/s
to 40 or
100 kbit/s
yes no
IPEH-001005
PCAN-Transceiver
TJA1055
Low-Speed-CAN
ISO 11898-3
20 kbit/s to
125 kbit/s
yes no
Do the following to replace a transceiver module:
Attention!
Electrostatic discharge (ESD) can damage or destroy
components on the circuit board of the PCAN-Router Pro. Take
precautions to avoid ESD when handling the circuit board.
1.
Disconnect the power supply.
2.
Unscrew the four screws at the upper corners of the
housing on the front and back.
3.
Remove the housing cover.
4.
Unscrew the two screws at the lower corners of the front
cover.
5.
Pull out with the front panel the board from the bottom side
of the housing to the front.