Figure 9: Position of the solder jumper fields for the 5-Volt supply
(JP5 lower position, JP6 upper position)
5-Volt supply
D-Sub connector Solder field
Without
(Standard)
Pin 1
Pin 9
Pin 1 and
pin 9
CAN 1
JP5
CAN 2
JP6
Risk of short circuit!
The 5-Volt supply is not protected
separately. Therefore, turn off the computer before you