PCAN-LIN – User Manual
33
Appendix C
Changes of
Hardware/Software
This section covers the most important changes of the hardware
and the software related to former versions.
C.1
PCAN-LIN Module
Property
Modules up to ser. no. 999 Modules from ser. no. 1000
Supply voltage
8 - 18 V DC
9 - 30 V DC
Max. bit rate RS-232
38,400 bit/s
115,200 bit/s
Microcontroller
(relevant for firmware
update)
XA-G49 LPC2194
LIN slave/master mode
(in Configuration Tool
“LIN Bus Termination”)
LIN termination is swit-
ched; during transmission
of a LIN header the master
mode is automatically
used, independent from the
setting
LIN termination is swit-
ched; master mode is expli-
citly switched on or off
C.2
PCAN-LIN Configuration Tool
Property
Version 1
Version 3
Number of Retries
Dropped
Bit Recognition Status
No possibility for changing
anymore; always active
Slave Mask
Integrated into table under
Frame Configuration
Entries on the
Profiles
Management
tab in the
LIN
branch
Slave ID + Data Configu-
ration: only a single ID
Entries possible for all IDs
under Frame Configuration