background image

 
 

Peak Atlas 

IT

 

 

RJ45 Network Cable Analyser 

Model UTP05 

 
 

 

Designed and manufactured with pride in the UK

 

 
 

 

User Guide 

 

©

 Peak Electronic Design Limited 2001/2013 

In the interests of development, information in this guide is subject to change without notice - E&OE 

 

GB05-7 

Summary of Contents for Atlas IT

Page 1: ...ble Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001 2013 In the interests of development information in this guide is subject to chan...

Page 2: ...damage the instrument socket and the terminator socket permanently leading to intermittent faulty readings that you can t rely on We are unable to provide warranty cover for misuse by using connectors...

Page 3: ...ntroduction 3 Important Notice 4 Background Information 5 Straight Through Cables Crossover Cables Other Cable Configurations Using Your Atlas IT 7 Analysis Results 9 Good Cables 9 Faulty Cables 14 Op...

Page 4: ...lines Displays the full connection pattern of the cable being analysed Compatible with optional Identified Terminators allowing multiple cable runs to be uniquely identified and analysed Supplied with...

Page 5: ...pment under test damage to the Atlas IT and invalidation of the manufacturer s warranty Additionally the absolute voltage limit of 80V between any pair of wires is stated for a maximum duration of 15...

Page 6: ...on for many networks however for universal compatibility all 8 connections are normally wired Straight Through Patch Cables The simplest network cables are simply called Patch Cables or Straight Throu...

Page 7: ...re actually a number of wiring configurations that can be used to produce a crossover cable The cable connection pattern shown above is the most common However the Atlas IT will recognise all variatio...

Page 8: ...wo short patch cables to allow for the testing of network cabling that is accessible only by sockets or a patch panel This is illustrated here Ideally the total cable length should not exceed 150 metr...

Page 9: ...ator and the local end has been connected to the Atlas IT instrument you are ready to perform a test Simply press the on test button The Atlas IT will first perform a short search procedure to determi...

Page 10: ...croll off when you re ready The next information to be displayed is the confirmation of the full connection pattern between the terminator Term and the Atlas IT Atlas As can be seen from the display h...

Page 11: ...Atlas IT User Guide July 2013 Rev 7 Page 10 This page is intentionally blank...

Page 12: ...Atlas IT User Guide July 2013 Rev 7 Page 11...

Page 13: ...Atlas IT User Guide July 2013 Rev 7 Page 12...

Page 14: ...Atlas IT User Guide July 2013 Rev 7 Page 13 This page is intentionally blank...

Page 15: ...ction s In this example the closest cable type match is an 8 wire crossover cable Pressing the scroll off button to view the next pages reveals the nature of the fault Here a flashing cross symbol ind...

Page 16: ...as the standard non identified terminators They are automatically recognised by the Atlas IT and the identity number is displayed along with the cable analysis results Up to 24 Identified Terminators...

Page 17: ...to serve as a reminder of course please seek guidance from a qualified person if you are unsure how to implement this information First the unit confirms the connection patterns for the two most comm...

Page 18: ...unction or leak damage The unit may continue to operate following a low battery warning performance however may be adversely affected To replace the battery unscrew the three screws to remove the rear...

Page 19: ...hat offer ease of use and durability RJ45 Breakout Adapter A unique adapter has been designed to enhance your Atlas IT for the analysis of un terminated cabling This is a professional assembly complet...

Page 20: ...r Dimensions 18 x 15 x 14 mm Notes 1 Dependant on quality of cable connections and influence of external interference 2 Specified for durations no longer than 60 seconds 3 Specified for durations no l...

Page 21: ...connected between the Atlas IT and the Terminator This will be displayed if the cable being analysed is not similar to any of the types stored in the Atlas IT The connection pattern will still be dis...

Page 22: ...ate of purchase This warranty covers the cost of repair or replacement due to defects in materials and or manufacturing faults The warranty does not cover malfunction or defects caused by a Operation...

Page 23: ...ndividual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic pro...

Reviews: