OPERATION 

Following are the typical steps involved in setup and routine operation: 

1.

 

Prepare TVs for use with RF-

HEMiS (see “

TV PREPARATION

”).

 

2.

 

Install RF-

HEMiS (see “

RF-HEMiS INSTALLATION

). 

3.

 

Configure RF-

HEMiS (see “SECURITY”, and “REMOTE ADMINISTRATION”).

 

4.

 

Configure the RF Clone Manager App (see 

“I

NITIAL RF CLONE MANAGER APP CONFIGURATION

”)

5.

 

For each different TV model, set one TV as desired then save the settings file to a USB drive.   

6.

 

Load all settings files, firmware updates, and splash images into the RF-HEMiS using the RF Clone Manager 
Application. 

7.

 

In the RF Clone Manager Application, start the RF broadcast which sends all the updates in a continuous 
loop. 

8.

 

When it is time to change TV settings, repeat steps 4 through 6. 

When set for automatic updating, TVs scan their programmed update channel each time the TV is turned off and 
back on.  If no new update information is found, the TV turns on normally.  When a new update is present, the TV 

will immediately download and apply it.  A message is displayed notifying the patient of what is happening.  The 
update may take up to 4 minutes. 

 

TV’s wit

h automatic updating disabled will not search for updates.  They may be manually updated by entering the 

setup menu and navigating to “Search for Updates Now” under the “

RF Cloning and FW Update

” menu. See TV’s 

user manual for more information. 

 

 
TV PREPARATION 

 

Updating Older TV Firmware 

Your TVs may need to be updated to a new firmware version using USB prior to using RF updating. The minimum 

firmware version required to use RF updating is listed under 

“Specifications”

 at the end of this manual. Complete 

firmware updating instructions can be found in the TV user manual.   

 

Enabling RF Updating 

Refer to the TV user manual for instructions on how to enable the RF-HEMiS on your PDi TVs.  
 

 

RF-HEMiS INSTALLATION 

Follow these steps for initial installation.  A LAN connection is optional. 

1.

 

Mount the RF-

HEMiS into an existing 19” head

-end rack. 

2.

 

Connect a quality coax cable (not included) from the RF-HEMiS output to the existing head-end RF 
combiner. 

3.

 

For ease of setup attach a keyboard, mouse, and VGA monitor (all not included) to the RF-HEMiS. If remote 
administration is desired, these accessories can be removed after the setup. 

4.

 

Apply AC power.  

5.

 

(Optional) To allow headless operation and automatic software updates, connect the RF-HEMiS to the LAN.   

6.

 

(Optional) Power the unit from an uninterruptable power supply (UPS) to avoid disruptions in service. 

Summary of Contents for RF-HEMiS PD890-1009

Page 1: ...mymedTV com USER MANUAL Document Number PD196 391R3 RF HEMiS Head end Management Integrated TV Server PD890 1009...

Page 2: ...TV Firmware 4 Enabling RF Updating 4 RF HEMiS INSTALLATION 4 SECURITY 5 REMOTE ADMINISTRATION 5 MAINTENANCE 5 INITIAL RF CLONE MANAGER APP CONFIGURATION 6 USING THE RF CLONE MANAGER APP 6 Overview 6 L...

Page 3: ...the head end It does this by inserting upgrade information into the building s RF coax cable plant Compatible TVs include PDi A series E series medTV and medTAB products Each model TV may be updated i...

Page 4: ...ng the patient of what is happening The update may take up to 4 minutes TV s with automatic updating disabled will not search for updates They may be manually updated by entering the setup menu and na...

Page 5: ...s available on all five ethernet ports not just the dedicated IPMI port IPMI allows for remote administration even when the RF HEMiS is powered down IPMI is shipped in the enabled state When it detect...

Page 6: ...clicking the checkbox next to their name and finally clicks the Broadcast button Loading Television Data Files TDFs To make use of the RF Clone Manager app at least one TDF is required Settings TDFs a...

Page 7: ...appear 3 Enter a meaningful update name into the Update Name field 4 Select the group that you are targeting from the Update Group dropdown menu 5 Click the Add TDF button to select and add a TDF file...

Page 8: ...pringboro Ohio 45066 USA www pdiarm com and www mymedTV com Phone 800 628 9870 RF CLONE MANAGER APP REFERENCE Main Screen The Main Screen of the RF Clone Manager app allows access to all other parts o...

Page 9: ...tton will begin the broadcast Clicking it while the broadcast is running will stop it 4 Broadcast Activity Indicator Indicates when updates are being broadcast 5 Saved Updates List All of the updates...

Page 10: ...in pixels The sizes are typically either 1920x1080 or 1366x768 See the TV User Manual for exact specification 5 File Clear Buttons Removes the specified file from the update 6 Cancel Button Ends the...

Page 11: ...modulation for the broadcast Default QAM 5 Broadcast Device Selector Allows the user to select between available broadcast adapters The RF HEMiS typically only has one broadcast device present 6 Save...

Page 12: ...defaults their Group IDs 5 Save Groups Button Save your custom label to memory SUPPORT INFORMATION PDi Communication Systems Inc Springboro OH www pdiarm com 800 628 9870 LIMITED WARRANTY PDi Communic...

Page 13: ...r of TV s updating simultaneously Unlimited Intuitive Graphical user interface YES Remote administration IPMI and Windows RDP TV Compatibility Minimum Firmware Version AxxA AxxB V1 16 ExxLEDA ExxLEDB...