background image

 

Communication  
Systems Inc.

 

PDI-P26LCDD Quick Start Guide 

Page 1 of 7 

Better Solutions Are Within Reach™ 

INSTALLATION INSTRUCTIONS 

 

PDi Communication Systems, Inc.   40 Greenwood Lane   Springboro, Ohio 45066 USA   PH +1-937-743-6010  PH +1-937-743-5664  

 

Document Number:  PD196I127R1.DOC 

  

PRODUCT ACCESSORIES 

(Not Included with TV) 

100mm VESA Wall Mount 

PD168-003 

Remote Control 

PD108-427 

¼” to 6-Pin Jumper Cable 

PD106-416 

¼” to ¼” Jumper Cable 

PD106-417 

VGA IN: Connection to the video output jack on your 
PC. VGA AUDIO IN: Connect the audio cable from the 
PC to the AUDIO IN of the set. 
NOTE TO CABLE TV INSTALLER 

This reminder is provided to call the cable TV systems 
installer’s attention to Article 820-40 of the National Electrical 
Code. The code provides guidelines for proper grounding 
and, in particular, specifies that the cable ground shall be 
connected to the grounding system of the building, as close 
to the point of the cable entry as practical. 

 

 

WARNINGS 

CAUTION :  

To reduce the risk of electric shock do not 

remove cover (or back). No user serviceable parts inside. Refer 
servicing to qualified service personnel. 
 

This symbol is intended to alert the user of the 
presence of uninsulated ‘dangerous voltage’ 
within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric 
shock to persons. 

 
This symbol is intended to alert the user of the 
presence of important operating and maintenance  
(servicing) instructions in the literature 
accompanying the appliance.

 

 

 

 
OVERHEAD FALLING HAZARD 

WARNING: To prevent injury, this apparatus 
must be securely attached to the wall in 
accordance with the installation instructions.  TVs 
can pose a striking hazard when mounted at an 
elevated position. 

 

RAIN AND MOISTURE 

WARNING:  To avoid the hazards of fire or 
electrical shock, DO NOT  expose this television 
to rain or moisture. 

 

OXYGEN ENVIRONMENT 

WARNING: Do not use in any oxygen tent or 
oxygen chamber. Such use may cause a fire 
hazard.

 

 

RAIN AND MOISTURE 

WARNING: To avoid the hazards of fire or 
electrical shock, DO NOT expose this television 
to rain or moisture.

 

 

WET LOCATION 

Apparatus shall not be exposed to dripping or 
splashing and no objects filled with liquids, such 
as vases, shall be placed on the apparatus.

 

FCC 

This equipment has been tested and found to comply with 
the limits for a Class B digital device, pursuant to part 15 of 
the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the 
equipment is operated in a residential or commercial 
installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one of more 
of the following measures: 
•  Reorient or relocate the receiving antenna. 
•  Increase the separation between the equipment and 
receiver. 
•  Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected. 
•  Consult the dealer or an experienced radio/TV technician 
for help. 

FCC ID:  WQ5P26LCDD

 

This device complies with Part 15 of the FCC Rules. 
Operation issubject to the following two conditions:      
(1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, 
including interference that may cause undesired 
operation 
 

MAINTENANCE AND SERVICING 

Never remove the back cover of the TV; this can expose you 
to high voltage and other hazards. If the TV does not 
operate properly, unplug it and call an authorized service 
center or PDI. 

 

CLEANING AND DISINFECTION

 

Clean the exterior of this television by removing dust with a 
lint-free cloth. CAUTION: To avoid damage to the surface of 
the television, do not use abrasive or chemical cleaning 
agents. 
 

DISCONNECTING DEVICE FROM MAINS 

Main plug is the disconnecting device.  The plug must 
remain readily operable. 

 

SERVICE INSTRUCTIONS 

CAUTION: These servicing instructions are for use by 
qualified service personnel only. 
To reduce the risk of electric shock, do not perform any 
servicing other than contained in the operating instructions 
unless you are qualified to do so. 

 

PRODUCT MODIFICATION 

Do not attempt to modify this product in any way without 
written authorization. Unauthorized modification could void 
the user’s authority to operate this product.

 

 

 

Summary of Contents for PDI-P26LCDD

Page 1: ...r moisture WET LOCATION Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus FCC This equipment has been tested and...

Page 2: ...tus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Copyright Disclaimer Trademarks COPYRIGHT PDi Communication Systems Inc claims proprietary right to...

Page 3: ...3 STANDARD WALL BRACKET Not supplied with TV 1 Refer to Figure 1 Select a location on the wall approximately 9 inches below the ceiling NOTE Do not locate AC Across Room Wiring and CATV Signal outlets...

Page 4: ...illow speaker that generates digital style control codes or a single button analog switch style pillow speaker A rear panel mounted switch allows use of different brands of pillow speakers and support...

Page 5: ...able access cover CAUTION Some hospital cable systems provide power voltage on the coaxial cable This TV is NOT designed to be powered via a coaxial cable Do not connect to a powered coaxial cable Dam...

Page 6: ...the direction button to select Signal 3 Press direction to select Air Cable STD Cable IRC or Cable HRC NOTE Most hospitals use the Cable STD signal style Auto Program The TV automatically scans each a...

Page 7: ...n off the TV s internal speakers 4 Press the SETUP button to return to the preceding menu Minimum Volume For pillow speakers with an adjustment thumbwheel volume control always set a minimum volume le...