Document Number: PD196-244R12
PD295-002
Page 13 of 29
PDi Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 USA PH 1-800-628-9870 FX 937-743-5664
TV Setup
–
Most PDi TVs (P14W, P16TV, P19TV, E-Series)
To establish communication to interface module the CCI port on the TV must be active and you must have a PDi
programming remote PD108-420 (not included). Follow the steps below:
1.
Press SETUP to enter the TV’s setup menu.
2. F
rom the setup menu select “Features”
.
3.
If the “Standby Power” setting shows in this menu, change it
to “Normal”. Some TV’s do not have
this setting so this step
can be ignored. Other TV’s may operate the
interface module
on any “Standby Power” setting. This can be determined by
trying it or contacting PDi.
4. From the initial
setup menu, select “Channels”.
5.
Change the “Pro:idiom” option
to “MTI Port”
or “Data Port”
.
Some TV’s do not have this setting
. In that case, this step can
be ignored.
6.
From the initial setup menu, select “
Sources
”.
Set each item
as detailed below.
The TV Source Setup must properly reflect the actual
connections to the TV. Incorrect settings will result in loss of
programming or the addition of blank signal sources. In most
installations, both cable/satellite and off-air programming is
delivered ov
er RF so the “
TV
Tuner” must be enabled. If the
cable/satellite channels are delivered over an alternate
method such as HDMI, then that source must be enabled. All
unused sources should be disabled.