background image

 

c. SETTI NG UP: SERI AL CONNECTI ONS - Printer 
 

GD 

Signal Ground 

OP 

RS232C Output 

I P 

RS232C I nput (Busy) 

 
Serial Protocol 

RS232C (+ / - 10v) 
8 Data Bits 
1 Stop Bit 
No Parity 
Baud Rate: Selectable 
ASCI I 
 

Printer Requirements: 

40 column RS232C compatible. 
Common Connections (typical example 25pin D Type – Epson LX300) 
Pin 3 (RXD) to OP  
Pin 7 (SG) to GD 
Pin 20 (DTR/ Busy) to I P 
Please refer to the printer manual for relevant pin descriptions/ terminations. 
 
 

D1. SETTI NG UP: SERI AL CONNECTI ONS - PC Output (type 1) 
 
( For details of Hyper-terminal Mode please consult manual G8-WI NDHT-120603) 

 

02 

6  

DP 

0A 

O

 

02

 =  Start  

6 digits weight plus placed decimal point

 (data MSD to LSD) 

Units

 i.e. kg, g, or te 

0A

 =  line feed 

0D

 =  Carriage return 

 

D2. SETTI NG UP: SERI AL CONNECTI ONS - PC Output (type 2) 

 

02  N/ G  S/ U 

+ / - 

1  2  3  4  5  6   DP  K  G  0A  OD  03 

 

02

 =  Start Message 

N/ G

 =  Nett or Gross 

S

= Stable

 U

= Unstable 

+  /  -

 =  polarity 

6 digits weight plus placed decimal point

 (data MSD to LSD) 

Units

 i.e. kg, g, or te 

0A

 =  line feed 

0D

 =  Carriage return 

03

 =  End of message 

 
 

e. SETTI NG UP: TI ME AND DATE 
 

Restore power whilst holding PRI NT key pressed. 
Release the POWER key. 
I nput 2 digits day/ month/ year/ hour/ minute each entry followed by MODE. 
For Example: < M= Mode key>  12M06M03M11M30M =  12/ 06/ 03 11:30am. 
Unit automatically returns to weighing mode. 

 

Summary of Contents for Apex Junior

Page 1: ...1 Apex Junior Cased Weighing Indicator Controller Document Version JG8 101215 Software Version H Board revision 1 4 onwards APPROVED DISTRIBUTORS OF Electronic Weighing Services USER MANUAL...

Page 2: ...ve 6 26v d c E Ground ii DC Applications Battery Versions B Battery Positive B Battery Negative V Adaptor DC 12VDC V Adaptor Earth Suitable Charging Adaptor approx 12vdc 300mA minimum Correct Procedur...

Page 3: ...t manual G8 WI NDHT 120603 02 1 2 3 4 5 6 DP K G 0A O D 02 Start 6 digits weight plus placed decimal point data MSD to LSD Units i e kg g or te 0A line feed 0D Carriage return D2 SETTI NG UP SERI AL C...

Page 4: ...The display will briefly prompt LOAD and then indicate E00000 awaiting the input of your test load value at this point check that the platform is empty then enter your required test load value via th...

Page 5: ...E key note the unit must have the necessary hardware options installed if printing or relay functions are selected Weigh Mode Print Mode Baud Select Line Feeds Function 0 Standard 0 Nett Kg 0 1200 0 1...

Page 6: ...O and then MODE key together Release the ZERO key and then the MODE key 4 PEAK HOLD To select peak hold mode press the MODE key Peak weight will then be displayed until the MODE key is pressed again t...

Page 7: ...ching operations from a loaded silo b One trip batcher mode MENU WEI GHMODE code 5 AUTOMATI C 5000x This mode controls a single relay continuously c Two trip batcher mode MENU WEI GHMODE code 6 AUTOMA...

Page 8: ...ad cells Conversion 24bit Sigma Delta A D I nput Range 0 150mV Linearity 0 0015 F S Temperature Drift 2 p p m per degree C Update Speed 7ips or 30ips user selectable I nternal Resolution 300 000 count...

Page 9: ...E DESCRIPTION EN55022 Radiated Emissions EN61000 4 4 Fast Burst Transient EN61000 4 3 Radiated Immunity EN61000 4 6 Conducted Immunity EN61000 4 2 Electrostatic Discharge 2014 35 EU Low Voltage Safety...

Reviews: