5.2.1 

System Set 

In the menu item "System Set" you can make some general settings. Use the Up/Down keys to 
select the desired setting, use the Power / OK key to confirm your selection. To exit the menu 
item, press the Exit key.  
 
Temp Unit:  

You can select °C or °F. 

Alarm HTL:  

Here you can set an alarm limit for the HCHO value. 

Clear Log: 

Select 

“clear“ to reset the data memory. 

Off Time: 

 You can select 

“never“, “30 min“, “60 min“ or “90 min“ to determine when the 

meter turns off automatically. 

Style: 

 

You can select different background colours. 

Language: 

You can select 

“English“ or “Chinese“. 

Brightness: 

You can set a display brightness between 10 % and 80 %. 

Buzzer Set: 

The key sounds can be activated or deactivated. 

5.2.2 

Time Set 

Here you can set the date and time. Use the Up and Down keys to adjust the respective value. 
Use the Power / OK key to move to the next item. 

5.2.3 

History 

In the "History", 10 data records are automatically saved at regular intervals. 
The data records can be reset in the settings. The recording then starts again. 

5.2.4 

Actual Data 

Here you can see real-time values of formaldehyde and the mass of volatile organic compounds 
in the environment. The air quality is determined from these values below. 

5.2.5 

Calibration 

A HCHO calibration is recommended at regular intervals to ensure the accuracy of the 
measurement results. Select "HCHO Calibration" with the Up and Down keys, confirm with the 
OK key and hold the device in the outside air. Press the OK key again to start the calibration. 
The meter performs a calibration automatically. 

You also have the possibility to set a correction value of the sensors. To do so, select a sensor 
with the Up and Down keys and confirm the selection by pressing the OK key. You will be asked 
again whether you want to change the settings. You can continue with the OK key or cancel the 
procedure with the Exit key. 

Battery level 

The battery status is indicated by green bars in the top right-hand corner of the display. The device 
can be charged via the USB interface. If the device is used continuously, it can also be charged 
permanently. 
 

 

Summary of Contents for PCE-RCM 8

Page 1: ...Particle Counter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chan...

Page 2: ...PCE Instruments Contents 1 Safety notes 1 2 Delivery contents 2 3 Specifications 2 4 Device description 3 5 Operation 3 5 1 Display modes 3 5 2 Menu 3 6 Battery level 4 7 Warranty 5 8 Disposal 5...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...999 g m 15 Laser scattering PM 10 0 999 g m 15 Laser scattering HCHO 0 001 1 999 mg m 15 Electrochemical sensor TVOC 0 001 9 999 mg m 15 Semiconductor sensor Temperature 10 60 C 14 140 F 15 Humidity 2...

Page 5: ...ter has been switched on The measurement cannot be stopped while the meter is on 5 1 Display modes To change the display mode press the Up or Down key You can choose between four different display mod...

Page 6: ...ervals The data records can be reset in the settings The recording then starts again 5 2 4 Actual Data Here you can see real time values of formaldehyde and the mass of volatile organic compounds in t...

Page 7: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 8: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Reviews: