Display description  

 

 

 

Symbol 

Designation 

Description 

99.7 

Measured value 

Display of the current measured value  

 

Battery indicator 

 Batteries charged or the meter is operated via the 

USB interface.  

 Batteries are 2/3 charged 

 Batteries are 1/3 charged 

 Batteries  are  discharged.  Please  replace  the 

batteries. 

Fe 
NFe 

Substrate 

Fe: magnetic material 
NFe: non-magnetic material 

µm 

Unit 

Adjustable units µm and mil 

^ / 

Limit value 

Is  displayed  when  the  set  limit  value  is  exceeded  or 
fallen below. 

17 

Number of 
measurements 

Number of measured values 

4.1 

Key description  

Symbol 

Designation 

Description 

 

On and off switch 

Press  and  hold  this  key  for  more  than  one 
second to switch the meter on and off 

 

Menu key, enter key 

Open  the  menu,  apply  changes  to  the 
settings.  

 

Calibration key, back 

Press this key to enter the calibration menu.  
Press  this  key  to  go  back  one  step  and  exit 
the menu. 

 

Arrow keys 

Change  parameters  and  select  the  desired 
function in the menu. 

 
 
 
 

 

Summary of Contents for PCE-CT 21BT

Page 1: ...Coating Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Las...

Page 2: ...off 4 7 Measurement 4 7 1 Continuous measurement 4 8 Menu 4 8 1 Menu structure 5 9 Calibration 5 9 1 Zero point calibration 6 9 2 One point calibration 6 9 3 Five point calibration 6 10 Data group 7...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...Fe Fe NFe Fe NFe Probe external internal external Measurement range 0 1500 m Resolution 0 1 m within meas range 0 99 9 m 1 m within meas range 100 1500 m Accuracy 1 m 2 of the coating thickness Units...

Page 5: ...terial m Unit Adjustable units m and mil v Limit value Is displayed when the set limit value is exceeded or fallen below 17 Number of measurements Number of measured values 4 1 Key description Symbol...

Page 6: ...ccur To carry out further measurements place the sensor on the next measuring spot Important In order to obtain the best results it is important to take measurements on a smooth and non slip surface D...

Page 7: ...OFF Unit m mil Device information About Sensor type Type Serial number Serial Hardware version Hardware Software version Software 9 Calibration To perform a calibration the meter has various function...

Page 8: ...asked whether you want to accept the calibration Press the key to save the change To discard the setting press the key 9 3 Five point calibration To perform a five point calibration first go to the ca...

Page 9: ...e memory 11 Limit value alarm To set limit values first go to the limit alarm menu Under the item Alarm on you can activate the limit alarm function You can set the limits as follows Upper limit value...

Page 10: ...this is not available the driver may be missing You can find the driver in the program folder under the driver folder If you have a 64 bit system use the installation file CP210xVCPInstaller_x64 If y...

Page 11: ...le device first download the Coatingmaster app Then switch on the Bluetooth function in the measuring device Now connect the coating thickness gauge via the app To do this select Coating_XXXX in the a...

Page 12: ...ngs to the app Setting Meaning Measuring sounds During a measurement a sound can be heard Measuring vibration When a measurement is made the vibration alarm is activated Alarm sounds When the limit is...

Page 13: ...any measurements at the edge Incorrect placement of the probe Always align the probe vertically and quickly with the surface Do not perform a measurement by force The probe must touch the test object...

Page 14: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 15: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: