7.6.1
Main screen of the Spindle Program
What should be noted in this window
Shortcuts in this window
The needed dimensions should be entered
correctly (can be changed later on, if
recommended).
Start new measurement or
restart measurement (all
acquired data will be lost)
Functions in this window
Enter the amount of
measurement points (positions)
-
Enter dimensions
-
Start measurement
-
View measurement results (available, if all needed
measurements are finished)
-
Save
Enter the distance between the
measurement points (near and
far)
Save results to a file (see
chapter 10
“Handling of the
Data Dialogue window
”
)
7.6.2
Measurement process
Mark two points on the machine bed (near and far),
where the receiver shall be placed on the tool slide
for future measurement.
Enter the distance between the near and the far measurement point. Mount the transmitter to the spindle
and the receiver to the tool slide. You can carry out a rough alignment, if needed. Press
, to get to the
measurement screen.
7.6.3
Carry out measurement
Press
, to carry out a measurement. Use
and
, to switch between the measurement points.
Press
, to return to the former screen
Transmitter label
position (here: top)
Blinking blue means
the currently selected
point
Saved measurement
value „-,--„ means that no
value is saved
Distance between the
measurement points
Means no possible
connection to the
sensors
Laser beam out of
the aim
Measurement data
not ready (wait)
Inclinator of the
receiver
Laser beam position
indicator