Manual 

             

Surface Testing

 

PCE-HT 225E 

 

 

Version 1.0 

Date of creation: 22.12.2015 

Date of last change: 06.09.2018

 

 

 

Summary of Contents for PCE-HT 225E

Page 1: ...nts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instr...

Page 2: ...4 4 1 Structure 4 4 2 Switching on 4 4 3 Operation 5 4 3 1 Measurement instructions 5 4 3 2 How to see the measurements values 6 4 3 3 Settings 7 4 3 4 Communication 8 5 Software 8 5 1 Installation 8...

Page 3: ...d by a qualified person Always use the device with both hands During the calculation of the test values errors can occur due to algorithmic rounding and inaccuracies If the values of the device and se...

Page 4: ...moothing the rough surfaces 1 x software 1 x user manual 4 Instructions 4 1 Structure Reset Infrared printer port 4 2 Switching on Press and hold the power button red button until the welcome display...

Page 5: ...o the computer Shut down Turns off the device with the software Manually it works with the Power button 4 3 1 Measurement instructions Select the main menu sampling and press OK to open a window param...

Page 6: ...n the device warns you and asks if you want to select the carbonation depth You can suppress this message by pressing Exit and change the values chronologically Calculate When you have recorded one co...

Page 7: ...sible values Backlight adjusts the screen brightness Reducing the brightness prolongs the battery life Volume adjusts the volume of the voice function Reducing the volume extends the battery life Auto...

Page 8: ...USB stick The computer can upload and download the data and measurement curves from the device 5 Software 5 1 Installation Insert the CD into your computer and follow the instructions Double click on...

Page 9: ...from the test instrument if the device was connected to the computer The component data are displayed in the component parameters You can also add and edit them 4 Delete component data make a right c...

Page 10: ...re use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 7 Contact If you have any questions about our ra...