PCE Health and Fitness 5000H User Manual Download Page 6

 

 

 

 

©  PCE Instruments 

 
 

Specifications 

 

Probe 

Type F and Type N 

Measuring range Type 

0 ... 5000 μm / 0 ... 5 mm / 0 ... 196 mils 

Measuring accuracy 
Type F 

± (2% + 1 μm) 

Resolution Type F 

0 ... 99.9 μm: 0.1 μm, 100 ... 999 μm: 1 μm  
> 1000 μm: 0.01 mm 

Measuring principle 
Type F 

Magnetic induction 

Smallest thickness of 
the base material 

0.02 mm 

Measuring range Type 

0 ... 3000 μm / 0 ... 3 mm / 0 ... 118 mils 

Measuring accuracy 
Type N 

± (2% + 1 μm) 

Resolution Type N 

0 ... 99.9 μm: 0.1 μm, 100 ... 999 μm: 1 μm  
> 1000 μm: 0.01 mm 

Measuring principle 
Type N 

Eddy current 

Smallest thickness of 
the base material 

0.05 mm 

Calibration 

One-point to four-point calibration, zero calibration 

Data storage 

Direct measurement (no measurement data storage), four data 
groups (automatic measurement data storage of up to 2000 
measured values) 

Statistical functions 

Number of measurements, average, minimum, maximum, 
standard deviation 

Measurement units 

μm, mm, mils 

Alarm 

Alarm limits adjustable, alarm symbol is displayed when limits are 
exceeded 

Minimum radius of 
curvature (convex)  

5 mm / 0.2 in 

Minimum radius of 
curvature (concave) 

25 mm / 1 in 

Smallest measuring 
surface 

Diameter of 20 mm / 0.8 in 

Maximum measuring 
rate 

2 x per second 

Data interface 

Data transfer via USB 

Power supply 

2 x 1.5V AAA batteries 

Menu languages 

German, English, Russian, Chinese 

Operating conditions 

0 ... 50°C / 32 ... 122°F, 20 ... 90% RH 

Storage conditions 

-10 ... 60°C / 14 ... 140°F 

Standards 

CE ROHS FCC 

Dimensions 

110 x 53 x 24 mm / 4.33 x 2.09 x 0.95 in 

Material housing 

ABS plastic 

Weight 

92 g / < 1 lb 

 

 

Summary of Contents for 5000H

Page 1: ...ing Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last ch...

Page 2: ...5 2 Basic Measurement Step 5 5 3 User Interface 6 5 4 Measure Mode Only Support Single Mode 7 5 5 Group Mode 7 5 6 Statistics 7 5 7 Probe Mode 8 5 8 Storage 8 5 9 Recall and Delete Readings 8 5 10 Hi...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...designed for non destructive fast and precise coating thickness measurement The principal applications lie in the field of corrosion protection It is ideal for manufacturers and their customers for o...

Page 5: ...de 2 High and low limit alarm 3 Probe mode AUTO MAG EDDY 4 Measuring readings display 5 Statistics display MIN MAX AVG 6 Auto power off indication 7 USB connecting indication 8 Measuring unit 9 Low ba...

Page 6: ...surement no measurement data storage four data groups automatic measurement data storage of up to 2000 measured values Statistical functions Number of measurements average minimum maximum standard dev...

Page 7: ...tery 2 The gauge will work in factory default settings for the first time including single measure mode AUTO probe mode direct group mode DIR etc 3 When power on if in direct group mode DIR the readin...

Page 8: ...Exit b Switch on off the backlight in measure mode Up Key a Move up or roll up b Increasing c Delete the last readings or whole group Down Key a Move down or roll down b Decreasing c Refresh LCD on t...

Page 9: ...thod of switch group mode a Press Left Key once to enter into menu mode Root directory b Press Up Key or Down Key to activate Options item and press Left Key once to enter in c Press Up Key or Down Ke...

Page 10: ...l group mode GENn readings and statistics will be stored and not be lost when power off In direct group mode DIR readings and statistics will be lost when power off Each group has individual high low...

Page 11: ...en you switch the work group the applied alarm settings will also be switched automatically Set high low limit for the current work group as below a Press Left Key once to enter menu mode Root directo...

Page 12: ...ss Up Key or Down Key to select intended item Press Left Key to confirm it 5 13 Data Download User can use the USB cable to connect the gauge with PC and download stored readings If USB connected the...

Page 13: ...asuring accuracy 6 Factors Affecting Measurement Accuracy User needs to know the factors of affecting measurement accuracy before using the gauge The factors are listed below Factors Principle Magneti...

Page 14: ...recalibrate the gauge according to practical applications 7 Calibration User should read chapter 6 Factors Affecting Measurement Accuracy firstly and must recalibrate the gauge according to measured...

Page 15: ...individual zero calibration and multi point calibration b When calibration up to 4 points user must clear the finished points firstly to restart c Readings measured before will not be affected by new...

Page 16: ...roup and the other groups will not be affected 8 Troubleshooting If the instrument gives no response and can t be turned on you can remove the battery and a few minutes later reinstall the battery and...

Page 17: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 18: ...975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www...

Reviews: