background image

Model CS640B92

LOOP POWERED, CURRENT OUTPUT, INDUSTRIAL VIBRATION SENSOR

Installation and Operating Manual

For assistance with the operation of this product,

contact PCB Piezotronics, Inc.

Toll-free: 800-959-4464

24-hour SensorLine: 716-684-0001

Fax: 716-684-3823

E-mail: [email protected]

Web: www.imi-sensors.com

Summary of Contents for IMI Sensors CS640B92

Page 1: ...TRIAL VIBRATION SENSOR Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail imi pcb com Web www imi sensors com ...

Page 2: ...ialized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For more information contact your local PCB Piezotronics distributor sales representative or factory customer service representative Returning Equipment If factory repair is required our representatives ...

Page 3: ...ation on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety precautions to avoid personal contact with this voltage This symbol on the unit indicates that the user should refer to the operating instructions located in the manual This symbol indicates safety ea...

Page 4: ...E 住房 O O O O O O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ... O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at least one of t...

Page 6: ...Model CS64XB9Y Series Industrial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 57751 MANUAL REVISION B ECN NUMBER 51542 ...

Page 7: ...ITORING Table of Contents Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements ESD Sensitivity Page 10 Warranty Servicing Warranty Service Return Procedure Page 11 Customer Service Page 12 ...

Page 8: ...ensor is used for process control or predictive maintenance There are many options in this series Please refer to specific specification sheets for further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration monitoring of critical applications Reduces sophistica...

Page 9: ...PAGE 4 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Dimension Drawing Inch mm ...

Page 10: ...g leads for all input and output connections and operate from a standard 2 wire 4 20mA loop Attach the positive input from the power supply to the red wire and the negative input from the power supply to the black wire Figure 1 wiring standard connection Figure 2 wiring loop powered Figure 3 wiring loop powered DC source Red Black Red Black ...

Page 11: ... the unit use the following formula to calculate the vibration level Vibration Output Measured Output 4mA x Full Scale Vibration Output 16mA Measured mA 640B90 640B91 B93 640B92 B94 4 00 0 0 ips pk 0 0 ips pk 0 0 ips pk 8 00 0 125 ips pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641B90 641...

Page 12: ... ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air The action of rolling out a cable and or Contact with a non grounded person The PCB solution for ...

Page 13: ...edure stated below A repair and or replacement quotation will be provided prior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site procedures Return procedure To expedite returned instrumentation contact a factory IMI applications engineer for a RETURN MATERIA...

Page 14: ...ed IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems or emergency situations arise call the IMI Hot Line at 716 684 0003 and an application specialist will assist you 3425 Walden Avenue Depew NY 14043 2495 Phone 716 684 0003 USA Fax 716 684 3823 INTL Fax...

Page 15: ...ramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Electrical Connector Integral Cable Integral Cable Electrical Connection Position Top Top Electrical Connections Positive 18 AWG Red 18 AWG Red Electrical Connections Negative 18 AWG Black 18 AWG Black Wire Length 36 in 91 44 cm All specifications are at room temperature unless otherwise specified In the in...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...safe with entity parameters of Ui V max 30V Ii I max lOOmA Pi 1W Ci 0 Li 1 06 uH when installed per installation Dwg 27534 Temp Code T4 Max Ambient 80 Deg C Models 9842 VCRT Vibration Sensors input rated 28V dc max 20mA intrinsically safe with entity parameters of Ui V max 30V Ii I max lOOmA Pi 1W Ci 0 Li 1 06 uH when installed per installation Dwg 36576 Temp Code T4 Max Ambient 80 Deg C Models EX...

Page 20: ...rs of Ui V max 28V Ii I max 120mA Pi 1W Ci 0 Li 1 06 uH when installed per installation Dwg 29987 Temp Code T4 Max Ambient 80 Deg C Note The x in the model code may be a 0 to 9 which denotes variations in frequency response range of the sensors The y in the model code may be a 0 to 9 which denotes variations in sensor sensitivity Models EX64xA0y Vibration Sensors input rated 28V dc max 20mA intrin...

Page 21: ... M 1987 R2009 Process Control Equipment CAN CSA C22 2 No 157 92 R2012 Intrinsically Safe and Non Incendive Equipment for Use in Hazardous Locations UL 913 7111 Ed Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I II and III Division 1 Hazardous Locations UL 916 4th Ed Energy Management Equipment CAN CSA E60079 0 07 Electrical apparatus for explosive gas atmospheres Part 0 Ge...

Page 22: ... nF Li 426 jiH when installed per installation Dwg 30538 Temp Code T4 Max Ambient 80 Deg C Notes 1 Sensor case must be bonded to ground according to Section 18 182 of the CEC Part 1 2 The x in the model code may be a 0 to 9 which denotes variations in frequency response range of the sensors The y in the model code may be a 0 to 9 which denotes variations in sensor sensitivity Models EX64xA0y Vibra...

Page 23: ...code may be a 0 to 9 which denotes variations in sensor sensitivity APPLICABLE REQUIREMENTS CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part IT C22 2 No 142 M 1987 R2009 Process Control Equipment C22 2 No 213 M1987 R2008 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations UL 916 4th Ed Energy Management Equipment UL 1604 3 31 Ed Electrical ...

Page 24: ...Canadian Electrical Code Part II C22 2 No 142 M1987 R2009 Process Control Equipment C22 2 No 213 M1987 R2008 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations UL 916 4th Ed Energy Management Equipment UL 1604 31d Ed Electrical Equipment for Use in Class I and II Division 2 Class III Hazardous Classified Locations ANSI ISA 12 12 01 2000 Nonincendive Electrical Equ...

Page 25: ...risdiction 2 The x is a series of letters and numbers in the model for different variations including variation in frequency response top cable entry side cable entry and other differences not critical to certification 3 M in the model number is optional and to include Metric threading adapters instead of English threading adapters CLASS 225802 PROCESS CONTROL EQUIPMENT For Hazardous Locations CLA...

Page 26: ...ied for Canada shall have all Caution and Warning markings in both English and French Additional bilingual markings not covered by the product standard s may be required by the Authorities Having Jurisdiction It is the responsibility of the manufacturer to provide and apply these additional markings where applicable in accordance with the requirements of those authorities The products listed are e...

Page 27: ...de or Month and Year of Manufacture Electrical Rating Hazardous Location Designation As per Product Section Applicable Temperature Code Applicable Ambient temperature range For EXHT and EXHTTO series DC symbol Certificate reference ie 2005 1632187 X Caution re Disconnection of circuits appears on referenced Installation Drawing EXHT and EXHTTO series models must be accompanied by documentation con...

Page 28: ... test Only the new model will be assessed with the latest applicable standards Any other testing that may be required to accomplish the reassessment will be quoted separately if necessary Update to Existing Report Certificate 1632187 Report 2655913 Expansion of the x and y variable digits Update to include new Model CS64xB9y Vibration Sensors Update to cover revisions to numerous drawings Update t...

Reviews: