background image

Model 3503A1060KG

TRIAXIAL HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER

Installation and Operating Manual

For assistance with the operation of this product,

contact PCB Piezotronics, Inc.

Toll-free: 800-828-8840

24-hour SensorLine: 716-684-0001

Fax: 716-684-0987

E-mail: [email protected]

Web: www.pcb.com

Summary of Contents for 3503A1060KG

Page 1: ...MS SHOCK ACCELEROMETER Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 6...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...icro electromechanical systems MEMS technology in which all structural and electronic components are manufactured in silicon using electronic microfabrication technologies MEMS devices are preferred i...

Page 7: ...ck the mounting torque after each measurement It s also recommended that a thread locking adhesive be applied to any threads if applicable Ceramic LCC leadless chip carrier packages available in this...

Page 8: ...ipment for repair it is recommended that the user confer with a factory application engineer or inter national representative to first troubleshoot the problem 11 0 Return Procedure To expedite the re...

Page 9: ...trical Connection Position Side Side Cable Type 026 8 conductor cable shielded PTFE 026 8 conductor cable shielded PTFE Cable Termination Pigtail Ends Pigtail Ends Cable Length 10 ft 3 05 m Mounting T...

Page 10: ...to others without the written consent of PCB Piezotronics Inc RECOMMENDED MOUNTING SURFACE SHOULD BE FLAT TO WITHIN 0003 008 TIR OVER 650 16 51 WITH A 32 08 FINISH FOR BEST RESULTS RECOMMENDED MOUNTI...

Page 11: ...R EQUIVALENT TYPICAL 2 3 51 76 3 4 76 102 4 4 4 FASTEN CABLE TO TEST STRUCTURE TYPICALLY WITHIN 2 3 51 76 OF SENSOR THEN FASTEN AGAIN WITHIN 3 4 76 101 OF PREVIOUS ATTACHMENT BETWEEN THE TEST STRUCTUR...