PBM PAVBL Series Operation And Maintenance Instructions Download Page 1

Page 1 of 8 

 

PAVBL Actuator Sizes 0052 thru 0270        
Operation and Maintenance Instructions 

 
TABLE OF CONTENTS: 

1.  SERVICE CONDITIONS 
2.  FUNCTION 
3.  STORAGE 
4.  MAINTENANCE 
5.  EXPLODED VIEW 
6.  DISASSEMBLING 
7.  ASSEMBLING 
8.  ADJUSTMENT 
9.  INSTRUCTIONS FOR CHANGING FAIL CLOCKWISE OR FAIL COUNTERCLOCKWISE OPERATION 
10.  TORQUE RATINGS, WEIGHTS AND OPERATION VOLUMES 

 
1   

Service conditions 

•  

AIR SUPPLY:

 dehumidified or lubricated air (standard).  Other non-corrosive gases or fluids are a possible 

alternative option, if compatible to the materials of the actuator components (internal parts and lubricant).  The maximum 
particle size must not exceed 40µm (ISO 8573 Part 1, Class 5). In order to prevent water condensation and/or solidification 
(ice, when actuator work below 0°C), the operating medium must have a dew point equal to 20°C or, at least 10°C below  the 
ambient temperature (ISO 8573 Part 1, Class 3).  

 

WORKING PRESSURE: 

minimum 29 PSI (2.5 BAR) 

– maximum 116 PSI (8 BAR) 

 

TEMPERATURE:  

 

o

 

minimum -

20˚C to m 85˚C  - standard execution – NBR gaskets 

o

 

minimum -

20˚C to m 150˚C - HIGH temperature execution – FKM (Viton) gaskets 

o

 

minimum -

40˚C to m 85˚C - LOW temperature execution – silicone gaskets 

o

 

Warning: in case of high or low temperature executions, a special grease is used as lubricant and such 
conditions may alter the torque generated by the actuator.  For further information please refer to PBM. 

 

ROTATION:

 

half turn, 0˚ – 90˚ adjustable ±5˚ in both end positions (double adjustment). 

 

LUBRICATION:

 The actuators are equipped with filled-for-life lubrication for normal service conditions. 

 

OPERATING TIME:

 Please refer to the technical documentation.  The operating time depends on various 

parameters such as air supply pressure, capacity of the air supply installation (size of piping, control equipment), 
type of valve and fluid, selected safety factor, temperature, etc.). 

 
 
 
 

 

 

For your safety and protection it is important that the following precautions be taken prior to 
working on the actuator. 

1.  Remove from the actuator all dust that may cause sparks; clean periodically to prevent 

dusting on the actuator.  Do not hit the actuators with metallic objects, as they may give off 
sparks. 

2.  The installation and the maintenance of pneumatic actuators must be assigned to trained 

and qualified personnel. 

3.  The use of the actuators out of the allowed temperature and pressure ranges may cause 

damage to the internal and external components. 

4.  Prior to any installation and maintenance of the actuator, close and disconnect any kind of 

power or air supply. 

5.  Disassembling the spring return type actuators (springs inside) may cause severe injuries.  

The maintenance must be assigned to qualified expert personnel in full observance of the 
instruction described at paragraph 5, otherwise, the actuator has to be returned to PBM. 

 

Summary of Contents for PAVBL Series

Page 1: ... alter the torque generated by the actuator For further information please refer to PBM ROTATION half turn 0 90 adjustable 5 in both end positions double adjustment LUBRICATION The actuators are equipped with filled for life lubrication for normal service conditions OPERATING TIME Please refer to the technical documentation The operating time depends on various parameters such as air supply pressu...

Page 2: ...essure acts on the surface of the pistons 12 causing their alternate movement which is converted into rotation standard 90 of the pinion 2 as a result the pneumatic actuators can be used for remote operation of valves 2 1 Double Acting ...

Page 3: ... O ring NBR 2 2 13 Anti friction Ring PTFE 15 Graphite 2 2 14 Thrust Block POM 2 2 15 Stop Bolt Retaining Nut Stainless Steel 2 2 16 Stop Bolt Stainless Steel 2 2 17 External Spring Steel 0 See Table Central Spring Steel 0 18 Internal Spring Steel 0 19 Left End Cap Die Cast Aluminum 1 1 20 Right End Cap Die Cast Aluminum 1 1 21 End Cap Seats NBR 2 2 22 End Cap Fixing Screw Stainless Steel 8 8 23 S...

Page 4: ... return SR type 6 For DOUBLE ACTING ACTUATOR Unscrew in crossed sequence the screws 25 for fastening the end caps 21 22 see Fig 2 7 For SPRING RETURN ACTUATOR Unscrew GRADUALLY in crossed sequence the screws 25 for fastening the end caps 21 22 Fig 2 Note the screws are long enough to hold the springs even if extended Loosen nuts 16 and unscrew completely screws 17 see Fig 3 8 Rotate the cylinder 1...

Page 5: ...hamber of the cylinder 1 and both pistons 12 provided with O ring 13 antifriction ring 14 and thrust block 15 The recommended lubricating grease is KLUBER TRIBO STAR 1EP 7 For the standard execution clockwise rotation opens press the pistons 12 into the cylinder 1 while turning the cylinder 1 in counterclockwise direction top view until the pistons come into contact see fig 17 8 Screw down the sec...

Page 6: ...screw L Put the actuator in counter clockwise position and check the adjustment Repeat until the desired adjustment is achieved Hold the screw in the correct position and tighten the nut 8 2 Adjustment procedure actuator in clockwise position Put the actuator in counter clockwise position supply compressed air for mod SR Adjust by means of the right adjustment screw R Put the actuator in clockwise...

Page 7: ... of the two pistons racks should be reversed This is Normal Fail Close Operation Note the location of the Piston Racks Right Piston Rack is in Front Just Behind Air Supply Parts This is Normal Fail Close Operation Note the location of the Piston Racks Right Piston Rack is in Front Just Behind Air Supply Parts For your safety and protection it is important that the following precautions be taken pr...

Page 8: ... A N A PAVBL453S 0270 8 14 387 9 230 N A N A 15 360 9 220 WEIGHTS AND VOLUMES DOUBLE ACTING ACTUATORS Actuator Model Rotate CCW Rotate CW PAVC series Actuator Model Air pressure at actuator psig Volume cu in Volume cu in Approx weight lbs 60 psig 80 psig Constant Torque Output PAVBL453D 0052 6 1 7 9 2 3 PAVBL453D 0052 133 179 PAVBL453S 0052 6 1 6 7 3 0 PAVBL453D 0063 238 321 PAVBL453D 0063 12 14 4...