5.2 Remote Control

Web

 

DXP-3800D can be controlled by WEB. User can type IP address of DXP-3800D in 

browser. It will show login pop-up. The default user name is root and password is 

12345. If you forget this username and password, you can use front panel button to 

change it. You can set it in System

HTTP login menu.   

 

5.2.1 Status 

User can monitor the status of input, output, Tuner and TS/IP. All information of 

every input source can be shown in this page. The output status and information 

can also be checked.   

Input Bitrate

—User can monitor TS status of TS(1~8)and IP IN here. 

 

 

Output Bitrate

—User can monitor video and audio decoding status here. 

 

Summary of Contents for DXP-3800D

Page 1: ...DXP 3800D 1 Professional 8 in 1 TS Processor User Manual http www pbi china com ...

Page 2: ... menu 13 5 1 3 Configuration Menu 14 5 1 5 System menu 15 5 2 Remote Control Web 17 5 2 1 Status 17 5 2 2 Configuration 18 5 2 2 1 Configuration Tuner 19 5 2 2 2 Configuration CI 20 5 2 2 3 Configuration Biss 20 5 2 2 4 Configuration ASI Output 21 5 2 3 Remux 22 5 2 4 TS IP 23 5 2 4 1 Gigabit Local 23 5 2 4 2 Gigabit Out 23 5 2 4 3 Gigabit In 24 5 2 5 System 25 6 Firmware Update 29 6 1 Firmware Up...

Page 3: ... point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of...

Page 4: ...operator serviceable parts inside Refer servicing to Beijing Jaeger trained and approved service engineers For the correct and safe use of the device it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that safety protection is impaired the device must be made in...

Page 5: ...uners and the powerful 8 CI decryption design make DXP 3800D one of the most competitive product in the head end market 2 Features 8 x Tuners Input Supports variety of input options DVB T2 T S2 S C DTMB ATSC ISDB T Supports DVB S2 Input Stream Identifier ISI optional and DVB T2 Multi PLP and SFN MIP pass through Built in TS re multiplexer receives from CI Slot1 to CI Slot8 and TS IP inputs 8 DVB C...

Page 6: ...ltage 0 13V 18V selectable LNB Band Selection Tone 0 22KHz selectable Satellite Selection Command DiSEqC 1 0 ISI ID 1 255 user configurable DVB C Tuner Input Connector Type 8 F type female 75Ω for Input Input Frequency Range 51 862MHz Input Level 51 75dBμV Symbol Rate 1 7MBaud ITU J 83 Annex A Constellation 16QAM 32QAM 64QAM 128QAM 256QAM Bandwidth 6MHz 7MHz 8MHz Input Return Loss 7dB typ DVB T T2...

Page 7: ...240 720 FEC Code Rate 0 4 0 6 0 8 ATSC Tuner Input compatible with ITU J 83 Annex B Connector Type 8 F type female 75Ω for Input Input Frequency Range 54 864MHz Input Level 75 7dBm ATSC 8VSB Symbol Rate 10 762MBaud Constellation 8VSB Roll off Factor 0 115 Bandwidth 6MHz TS Processing TS Input Management Demux and Remux among IP Input and CI1 to CI8 Input TS Output Management ASI1 to ASI8 output di...

Page 8: ...nnels 8xchannels directly pass through the TS from CI1 to CI8 1xchannel output the TS from Remux MPTS IP out without IP in 2 Max 430Mb s for 128xchannels SPTS IP out the TS from one source without IP in 3 Max 80Mb s for full duplex 1xchannel MPTS Protocol UDP RTP Multicast Unicast IGMPv3 ARP Alarm Connector Type 1 D sub 9 male Switching Condition User Defined Control Monitoring Connector Type 1 RJ...

Page 9: ...ature 10 60 Operating Humidity 10 90 non condensed Certification EMC EN 55024 1998 A1 2001 A2 2003 EN 55022 2006 A1 2007 EN 61000 3 2 2006 EN 61000 3 3 2008 FCC Part 15 Class B LVD EN 60950 1 2006 A11 2009 For more information about digital audio pass through please contact our sales representative ...

Page 10: ...lease refer to details in the table 10 LED OFF The equipment works properly LED Tuner Lock LED ON Tuner input is locked LED OFF Tuner is un locked LCD Display Display menus submenus and its parameters Cursor Keys UP DOWN LEFT RIGHT Used to navigate through the menu system ENTER key Confirm a selection then return to previous menu EXIT Key Exit and return to previous menu Control RJ 45 Ethernet por...

Page 11: ...I Output ports in Remux 1 2 Power Supply Double Power Supply AC 90 250V 50 60Hz input 4 3 RS 232 Serial Port The RS 232 port is used for equipment software debug use its pin definition is shown in the table The parameter settings are No Parity bit 38400 Bauds 8 data bits 1 Stop bit Pin Pin Function 1 N C 2 TXD 3 RXD 4 N C 5 GND 6 N C 7 N C 8 N C 9 N C 4 4 Management Ethernet Port The Management po...

Page 12: ...o the IP Network 4 5 TS over IP Ethernet Port The TS over IP port is an option by adding the daughter board inside the rack The default setting is as following IP address 10 10 10 10 2 nd IP address 10 10 10 20 for option DCH 5100P 32x if equipped Sub Mask 255 255 255 0 Gateway 10 10 10 1 Depending on the option selected by the customer this TS over IP port is either 10 100 Base T or 100 1000 Base...

Page 13: ...r can set IP address network mask and IP gateway press ENTER to select the option and use LEFT or RIGHT to move the cursor between digits and use UP or DOWN to change the value until the right value then press ENTER to make the selection Customers can use UP DOWN LEFT RIGHT ENTER EXIT keys from front panel to navigate in the menus select and confirm the parameters in LCD screen 5 1 2 Main menu Use...

Page 14: ...including Tuner CI settings AV decoder ASI output BISS SDI TS over IP input only when the TS IP streaming board is installed and so on Choose Configuration and press UP or DOWN to scroll the sub menus press ENTER to go into the sub menus There are ten sub menus to configure Slave Board Setup Tuner1 8 setting CI BISS Remux TS IP ASI Out Submenu Name Description Slave Board Setup Tuner Tuner 1 Tuner...

Page 15: ...ting Remux Bit Rate To set the Max bit rate of the Remux output Packet Size To choose 188Byte or 204Byte for the Packet Size TS ID To set the TS ID Remove CA To choose Off or On for the Remove CA Insert EIT To choose Off or On for the Insert EIT ON ID To configure the Original Network ID Output Program To select which services will be output by Remux TS IP Bypass ASI Out Bypass 5 1 5 System menu I...

Page 16: ... configure the product name of the device Version Info To display some properties of the device such as software version Factory Settings The switch to make factory default setting Machine Type Password Bypass MAC Address To configure the MAC address of the device S N To configure the serial number of the device External Board MAC To configure the MAC address of the device Web Login HTTP Login To ...

Page 17: ...e and password you can use front panel button to change it You can set it in System HTTP login menu 5 2 1 Status User can monitor the status of input output Tuner and TS IP All information of every input source can be shown in this page The output status and information can also be checked Input Bitrate User can monitor TS status of TS 1 8 and IP IN here Output Bitrate User can monitor video and a...

Page 18: ...DXP 3800D 18 Tuner Status User can Tuner signal status here TS IP Status User can TS over IP status here 5 2 2 Configuration Set parameters of tuner input CI Biss and ASI Output ...

Page 19: ...bol rate of QPSK signal its range is from 1000 to 45 000KBaud PLS Gold Code To configure the PLS gold code its range is from 0 to 262 141 Frequency Offset High To ensure the tuner locks the specific signal its range is from 1000K to 5 000KHz Frequency Offset Low To ensure the tuner locks the specific signal its range is from 5 000K to 1 000KHz The condition is Freq Offset Low Real IF Setting IF Fr...

Page 20: ... the CI slots When select the right Input Source the programs will be listed in the table you can descramble the right programs Click Apply button to submit or click Cancel button to cancel 5 2 2 3 Configuration Biss Biss 1 8 Set parameters of BISS Descryption DXP 3800D supports BISS 1 and BISS E mode Click Apply button to submit or click Cancel button to cancel ...

Page 21: ...BISS 1 mode and input ID and Key in BISS E mode BISS Program To configure the programs should be decrypted 5 2 2 4 Configuration ASI Output Set parameters of ASI output There are two ASI output ports you can select the input source in this page Click Apply button to submit Refresh button to refresh latest status of settings or click Cancel button to cancel ...

Page 22: ...ixed TS you can type button to delete the selected programs Please don t forget click Apply button to save the setting or click Cancel button to cancel Menu Name Description Packet Size To choose 188Byte or 204Byte for the Packet Size Bit Rate kbps To configure the output total bit rate TS ID To configure the TS ID Valid Bit Rate kbps To display the valid bit rate of the TS output Insert EIT To ch...

Page 23: ...P page will show Gigabit Out Gigabit In and Gigabit Local Gigabit Mode Multiple Output only 5 2 4 1 Gigabit Local Gigabit Local is selected the following page will be shown Click Apply button to submit or click Cancel button to cancel 5 2 4 2 Gigabit Out Gigabit Out is selected the following page will be shown Click Apply button to submit or click Cancel button to cancel ...

Page 24: ...DXP 3800D 24 5 2 4 3 Gigabit In Gigabit In is selected the following page no information Gigabit Mode Multiple Output only ...

Page 25: ... Upgrade page In Device page user can set the Product name Model number and Web auto refresh Time Click Apply button to submit or click Cancel button to cancel In the page user can also set the Gigabit Mode if choose the Full Duplex in configuration Gigabit In is selected the following page will be shown Click Apply button to submit or click Cancel button to cancel ...

Page 26: ...DXP 3800D 26 In Network Setting page user can set the network management parameters and the MAC will be shown Click Apply button to submit or click Cancel button to cancel ...

Page 27: ...sion page user can read the software version In Web Login page user can set your own username and password to access webGUI of DXP 3800D In Factory Default page user can restore factory default configuration of DXP 3800D ...

Page 28: ...DXP 3800D 28 In System Reboot page user can reboot DXP 3800D ...

Page 29: ...version in the equipment It is impossible to make firmware downgrade in automatic mode If the firmware version in the USB key is equal or lower than the version in the equipment user can use the Force Mode in the System menu System USB Force Upgrade The equipment will reboot automatically when the software upgrade is finished After the firmware upgrade please check the new version from the menu of...

Page 30: ... Important DON T switch off the equipment and your PC during the software upgrade Open the IE browser and type ftp 10 10 70 48 in the address bar and press Enter If the network configuration is correct you can open the FTP folder without any error as shown below Open MS DOS window by typing Start on the lower left quarter of Windows OS Select Run and key in cmd in dialog and press Enter Type the c...

Page 31: ...e equipment under software upgrade as below Type Enter to go into the login window Use root as login name and 12345 as password Key in the command upgrade and press Enter The upgrade process will be launched Figure 4 Open MS DOS Window Figure 5 Login Menu ...

Page 32: ... control page 6 3 Firmware Upgrade from WEB Open the Web control page of the equipment Go to the upgrade function in the SYSTEM menu Browse the file named Target tgz click Upload file button then the firmware is automatically uploaded in the memory of the equipment After the upgrade check the version number in the SYSTEM menu Figure 6 Upgrading ...

Page 33: ...pection and configuration The POWER Indicator LED will always light on during working If not use the device please pull out the AC plug If user wants to reboot device please leave it for at least 5 seconds after shutting it down 8 Accessories CD ROM 1PC Power cable 1PC ASI cable 1PC Balance audio to RCA cable 2PC BNC to RCA Adapter 4PC Certificate of quality Guarantee card 1PC ...