TO THE  INSTALLER:

This manual is the property of the owner and must be affixed near the boiler for
future reference.

TO THE  OWNER:

This boiler should be inspected annually by a Qualified Service Agency.

TO BE COMPLETED BY THE INSTALLER

Service Agency

Phone No.

Address

Boiler Model No. GM-

Serial No.

Date of Installation:

If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

W

WA

AR

RN

NIIN

NG

G

– Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

–  WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire
department.

– Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

GM8070 R3 (10/06-1M)

Printed in U.S.A.

PB HEAT, LLC

PO BOX 447 • NEW BERLINVILLE, PA 19545-0447

Summary of Contents for Series GM

Page 1: ...ty damage personal injury or loss of life W WA AR RN NI IN NG G Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMEL...

Page 2: ...are present in the combustion area The control is a single use device If the control is activated to interrupt boiler operation do not attempt to place boiler in operation Contact a qualified service...

Page 3: ...calls for heat 2 Limit senses boiler water temperature Prevents operation until water temperature falls approximately 15 F 8 C below the cut out temperature 3 Automatic vent damper if used opens 4 Ga...

Page 4: ...rs Note If pilot flame is not detected main and pilot gas are automatically turned off Refer to Paragraph B above to resume operation c Spark Ignited Pilot Pilot flame detected 1 Main gas on igniting...

Page 5: ...Figure 2 Operating Instructions SmartValve Intermittent Ignition boiler model suffix SV 5...

Page 6: ...Figure 3 Operating Instructions Spark Ignition boiler model suffix SPRK 6...

Page 7: ...Figure 4 Lighting Instructions Standing Pilot boiler model suffix STDG 7...

Page 8: ...ify operation follows Sequence of Operation see page 3 3 View flames through observation port See Figure 1 4 Check pilot flame See Figures 5 and 6 The pilot flame should be medium blue covering approx...

Page 9: ...l For continued safe operation a qualified service agency must provide a more detailed inspection of burners heat exchanger and vent system and provide maintenance as specified in the Installation Ope...

Page 10: ...entilation Wear a NIOSH MSHA approved respirator Wear long sleeved loose fitting clothing and gloves to prevent skin contact Wear eye goggles Minimize airborne dust prior to handling and removal by wa...

Reviews: