Payne PY3G Series Product Data Download Page 1

1

Product Data

PY3G

13 SEER SINGLE PACKAGED AIR CONDITIONER AND

GAS FURNACE SYSTEM WITH R--410A REFRIGERANT

SINGLE AND THREE PHASE

2--5 NOMINAL TONS (SIZES 024--060)

A09581

Fig. 1 -- Unit PY3G

Single--Packaged Products with Energy--Saving Features and

R--410A refrigerant.

S

Up to 13.5 SEER

S

Up to 81% AFUE

S

Factory--Installed TXV

S

Multi--Speed Blower--Standard

S

Direct Spark Ignition

S

Low Sound Levels

FEATURES/BENEFITS

One--piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.

Easy Installation

Factory--assembled package is a compact, fully self--contained,

combination gas heating/electric cooling unit that is prewired,

pre--piped, and pre--charged for minimum installation expense.
These units are available in a variety of standard and optional

heating/ cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are

lightweight and install easily on a rooftop or at ground level. The

high tech composite base eliminates rust problems associated with
ground level applications.

Convertible duct configuration

Unit is designed for easy use in either downflow or horizontal

applications. Each unit is easily converted from horizontal to
downflow with the two standard duct covers. Downflow operation

is easily provided in the field to allow vertical ductwork

connections. The basepan utilizes knockout style seals on the
bottom openings to ensure a positive seal in the horizontal airflow

mode.

Efficient operation High--efficiency design

offers SEER

(Seasonal Energy Efficiency Ratios) of up to 13.5 and AFUE

(Annual Fuel Utilization Efficiency) ratings as high as 80.4%.

Energy--saving, direct spark ignition

saves gas by operating only

when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit

for propane conversion is available for all units.

PY3G have dedicated Low NOx units

designed for California

installations. These models meet the California maximum oxides of

nitrogen (NOx) emissions requirement of 40 nanograms/joule or
less as shipped from the factory and MUST be installed in

California Air Quality Management Districts where a Low NOx
rule exists. Low NOx option is available on single phase models

only.

Durable, dependable components Compressors

are designed

for high efficiency. Each compressor is hermetically sealed against

contamination to help promote longer life and dependable
operation. Each compressor also has vibration isolation to provide

quieter operation. All compressors have internal high pressure and

overcurrent protection.

Monoport inshot burners

produce precise air--to--gas mixture,

which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,

requires cleaning. All gas furnace components are accessible in one

compartment.

Turbo--tubular

t

heat exchangers

are constructed of aluminized

steel for corrosion resistance and optimum heat transfer for
improved efficiency. The tubular design permits hot gases to make

multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the

hot gases to stay in close contact with the walls, improving heat

transfer.

Direct--drive high efficiency brushless DC multi--speed blower

motor

is standard on all PY3G models.

Direct--drive PSC condenser--fan motors

are designed to help

reduce energy consumption and provide for cooing operation

down to 40

_

F (4.4

_

C) outdoor temperature. Motormaster

r

II low

ambient kit is available as a field--installed accessory.

Thermostatic Expansion Valve

-- A hard shutoff, balance port

TXV maintains a constant superheat at the evaporator exit (cooling

cycle) resulting in higher overall system efficiency.

Refrigerant system

is designed to provide dependability. Liquid

filter driers are used to promote clean, unrestricted operation. Each

unit leaves the factory with a full refrigerant charge. Refrigerant
service connections make checking operating pressures easier.

Summary of Contents for PY3G Series

Page 1: ...ave dedicated Low NOx units designed for California installations These models meet the California maximum oxides of nitrogen NOx emissions requirement of 40 nanograms joule or less as shipped from th...

Page 2: ...n 19 05 mm wide perimeter flange makes frame mounting on a rooftop easy TABLE OF CONTENTS Features Benefits 1 2 Model Number Nomenclature 3 ARI Capacities 4 Physical Data 5 6 Options and Accessories 7...

Page 3: ...s 060 5 0 Tons W Heat Input Size Btuh 040 40 000 060 60 000 090 90 000 115 115 000 130 130 000 Electrical Supply N 208 230 1 60 P 208 230 3 60 E 460 3 60 040 A Series Options TP Base unit with tin pla...

Page 4: ...ciency information available from your retailer Gas Heating Capacities and Efficiencies UNIT PY3G HEATING INPUT Btuh OUTPUT CAPACITY Btuh TEMPERATURE RISE RANGE F C AFUE 024040 030040 40 000 32 000 30...

Page 5: ...0 1200 1200 1400 1400 800 10x10 254x254 1 2 1050 800 10x10 254x254 1 2 1050 1000 10x10 254x254 1 2 1050 1000 10x10 254x254 1 2 1050 1200 11x10 279 4x254 3 4 1000 1200 11x10 279 4x254 3 4 1000 1400 11x...

Page 6: ...1750 1600 11x10 279 4x254 1 0 1075 1600 11x10 279 4x254 1 0 1075 1600 11x10 279 4x254 1 0 1075 1750 11x10 279 4x254 1 0 1040 1750 11x10 279 4x254 1 0 1040 1750 11x10 279 4x254 1 0 1040 FURNACE SECTION...

Page 7: ...ssor motor life Corporate Thermostats provide control for the system heating and cooling functions Thermostat models are available in both programmable and non programmable versions Crankcase heater p...

Page 8: ...ISCHARGE REPLACEMENT PANEL HOLE FOR ECONOMIZER WIRING HARDNESS DOOR LATCH ANGLE HINGED FILTER ACCESS DOOR INSTALL FILTER ACCESS DOOR STICKER ALUMINUM FILTER RAINHOOD 11 13 32 17 13 32 16 1 4 EV APORAT...

Page 9: ...9 UNIT DIMENSIONS PY3G024 036 A08598 PY3G...

Page 10: ...10 UNIT DIMENSIONS PY3G042 060 A08599 PY3G...

Page 11: ...F Return opening B X C Insulate d deck pan Short Support CTyp G E F G D E A05308 UNIT SIZE CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM E IN MM F IN MM G IN MM PY3G024 036 CPRFCURB006A00 8 203 11 2...

Page 12: ...4 under Cooling Capacities tables 3 Select heating capacity of unit to provide design condition requirement In the Heating Capacities and Efficiencies table note that the unit 036090 will provide 72 0...

Page 13: ...09 57 13 8 23 78 23 78 1 68 22 21 22 21 1 87 20 64 20 64 2 08 19 06 19 06 2 31 17 46 17 46 2 56 15 85 15 85 2 82 62 16 6 24 57 22 03 1 68 22 75 20 99 1 87 20 94 19 93 2 08 19 15 18 83 2 31 17 46 17 4...

Page 14: ...03 57 13 8 30 51 30 51 2 12 28 39 28 39 2 33 26 27 26 27 2 56 24 14 24 14 2 80 22 01 22 01 3 07 19 87 19 87 3 35 62 16 6 30 85 28 45 2 12 28 49 28 24 2 33 26 26 26 26 2 56 24 14 24 14 2 80 22 01 22 0...

Page 15: ...0 0 04 57 13 8 37 24 37 24 2 43 34 27 34 27 2 76 31 33 31 33 3 12 28 44 28 44 3 52 25 58 25 58 3 96 22 76 22 76 4 44 62 16 6 37 97 34 65 2 43 34 64 32 72 2 76 31 35 31 35 3 12 28 43 28 43 3 52 25 58 2...

Page 16: ...04 57 13 8 42 24 42 24 2 98 39 61 39 61 3 35 36 97 36 97 3 76 34 32 34 32 4 18 31 63 31 63 4 63 28 88 28 88 5 08 62 16 6 43 11 40 44 2 95 40 11 38 38 3 34 37 15 36 28 3 75 34 31 34 31 4 18 31 62 31 62...

Page 17: ...0 05 57 13 8 48 55 48 55 3 35 45 46 45 46 3 74 42 35 42 35 4 16 39 21 39 21 4 61 36 04 36 04 5 10 32 81 32 81 5 60 62 16 6 49 62 44 99 3 35 46 10 43 02 3 74 42 60 40 97 4 16 39 21 39 21 4 61 36 04 36...

Page 18: ...02 57 13 8 60 39 60 39 4 33 56 80 56 80 4 74 53 18 53 18 5 18 49 50 49 50 5 66 45 74 45 74 6 16 41 85 41 85 6 68 62 16 6 61 11 55 94 4 33 57 07 53 59 4 74 53 18 53 18 5 18 49 50 49 50 5 66 45 74 45 7...

Page 19: ...issible Do not extrapolate 3 The following formulas may be used Sensible capacity Btuh 1 10 x cfm tldb tedb Wet bulb temperature corresponding to enthalpy air leaving evaporator coil hlwb tlwb total c...

Page 20: ...ed Low Pink CFM 851 777 675 591 475 Heating Rise oF 52 NA NA NA NA NA NA NA NA Heating Rise oC 29 NA NA NA NA NA NA NA NA Medium2 Red CFM 941 851 774 684 576 479 Heating Rise oF 47 52 NA NA NA NA NA N...

Page 21: ...1154 1090 1027 977 894 828 762 Heating Rise oF 34 36 39 41 43 45 50 54 NA Heating Rise oC 19 20 21 23 24 25 28 30 NA Medium2 Red CFM 1354 1290 1226 1158 1102 1046 981 918 843 Heating Rise oF 33 34 36...

Page 22: ...ow Pink CFM 1345 1282 1235 1194 1140 1095 1027 974 921 Heating Rise oF 51 53 55 57 60 62 NA NA NA Heating Rise oC 28 29 31 32 33 35 NA NA NA Medium1 Red CFM 1505 1452 1413 1358 1323 1282 1234 1169 113...

Page 23: ...d Low Pink CFM 1457 1404 1367 1318 1284 1233 1197 1144 1104 Heating Rise oF NA NA NA NA NA NA NA NA NA Heating Rise oC NA NA NA NA NA NA NA NA NA Medium2 Red CFM 1736 1695 1642 1601 1553 1512 1465 142...

Page 24: ...A NA NA NA NA NA Med Low Pink CFM 1678 1635 1602 1558 1513 1474 1438 1404 1349 Heating Rise oF 57 59 60 62 64 65 NA NA NA Heating Rise oC 32 33 33 34 35 36 NA NA NA Medium2 Red CFM 1962 1915 1880 1843...

Page 25: ...3 8 3 8 3 5 3 5 3 2 90 000 Orifice No Qty 38 3 41 3 41 3 42 3 42 3 Manifold Press IN W C 3 8 3 8 3 5 3 5 3 2 115 000 Orifice No Qty 33 3 36 3 36 3 36 3 38 3 Manifold Press IN W C 3 8 3 8 3 7 3 4 3 7...

Page 26: ...FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX FIELD SUPPLIED SUPPLY AIR FLEXIBLE DUCT ROOF MOUNTING CURB A09607 INDOOR THERMOSTAT DISCONNECT PER NEC FROM POWER SOURCE RETURN AIR TOP COVER FROM GAS LI...

Page 27: ...scharge orientation do not require duct covers Airflow Units are draw thru in the cooling mode and blow thru in the heating mode Maximum cooling airflow To minimize the possibility of condensate blow...

Page 28: ...15 PY3G048115 6 2 41 0 0 5 3 8 0 7 12 1 15 PY3G048130 6 2 41 0 0 5 3 8 0 3 12 1 15 PY3G060090 7 8 52 0 0 5 3 8 0 3 14 3 20 PY3G060115 7 8 52 0 0 5 3 8 0 7 14 0 20 PY3G060130 7 8 52 0 0 5 3 8 0 3 14 0...

Page 29: ...29 TYPICAL WIRING SCHEMATIC 208 230 1 60 A08052 PY3G...

Page 30: ...30 TYPICAL WIRING SCHEMATIC 208 230 3 60 A08053 PY3G...

Page 31: ...31 TYPICAL WIRING SCHEMATIC 460 3 60 A08010 PY3G...

Page 32: ...em thermostat calls for cooling 24 V is supplied to the Y and G terminals of the thermostat This completes the circuit to the contactor coil C and indoor evaporator fan relay IFR The normally open con...

Page 33: ...direct drive as shown on equipment drawings 2 Fan wheel shall be made from steel be double inlet type with forward curved blades with corrosion resistant finish Fan wheel shall be dynamically balance...

Page 34: ...Package Shall consist of a solid state control and condenser coil temperature sensor for controlling condenser fan motor op eration which shall allow unit to operate down to 0_F 17_C outdoor ambient t...

Reviews: