background image

11

Summary of Contents for BLU Master Controller

Page 1: ...Master Controller Installation Guide Ins 60005 GD US ...

Page 2: ...s such debris may create a fire or shock hazard Unpack the unit with care and inspect for transit damage If damage is suspected the unit must not be used or tested but you should immediately contact Paxton technical support to assist in troubleshooting or to provide return authorization INSTALLATION Only qualified and trained personnel familiar with this type of product and who fully understand th...

Page 3: ...his housing should be fixed to the surface with suitable fasteners screws and wall plugs are provided for this in the fitting kit Also provided are cable ties to secure the cabling and a smaller securing screw for the lid ...

Page 4: ...For a fail safe lock maglock wire 12V 24V to the N C terminal instead of N O Repeat the Exit button connections for door 2 if a second door is required Diode Door 1 Reader Keypad Door 2 Reader Keypad To Expansion controller Use shielded data cable Belden 9841 single pair or technical equivalent TCP IP Ethernet connection Use Cat5 or Cat6 cable Tamper switch cabinet ...

Page 5: ...re that if you dont have an Ethernet connnection then by default the unit will attempt to connect through the GSM network This would require the purchase of a Paxton BLU Modem and activation license Contact 1 Orange Door 1 contact closed Contact 2 Orange Door 2 contact closed RS485 OUT Orange Unit receiving data OK Green Flashing on and off to indicate trying to connect 0 5 secs OK Green Flashing ...

Page 6: ...ivated To purchase this please contact Paxton at 877 438 7298 option 7 note that you will need the serial number and activation code listed on the front of the master controller The Paxton BLU Control Master unit requires configuration and initialization before use To do this will require a Windows PC or laptop with USB ports and internet access or having the proper installer tool previously insta...

Page 7: ... Device Manager and then selecting Ports COM LPT Now click on View Device Details and then on the Get Details button Follow the instruction by power cycling the Master unit so that it goes into its bootloader and provides the required details Tip You can power cycle the Master unit by removing and replacing the two pin power plug at the top right of the controller a two pin plug marked 12V 24V and...

Page 8: ...re following the firmware update The Communication Settings button displays a number of settings with default values see below You can query the exisiting settings and edit those if you wish You may select the Default Communication Method from the drop down list The default setting is Auto meaning that the controller will attempt to use the TCP IP Ethernet connection as long as one is available If...

Page 9: ...firmware to install You have now completed the initial configuration of the master controller power cycle the unit and log into your Paxton BLU account my paxton blu com go to Help and select Quick Start Guide to assist you in setting up the controller in your customer and site n Electrical Voltage 11V DC 24V DC 20 PCB Current depending on activity 200 mA Relay switchable voltage 24V DC 20 Relay s...

Page 10: ...eatures Number of Cards 100 000 Number of PINs 100 000 Access levels per customer 1000 Time zones 1 sec 512 Door open time 99 999 sec Data lines per system Unlimited Doors per controller 2 Reader ports per controller 2 Readers Keypads per port 2 Controllers per data line 25 50 doors Data retention after total power loss 7 days Events stored in controller with no server connection 200 000 Dimension...

Page 11: ...11 ...

Page 12: ...18 08 2017 Paxton Ltd Ins 60005 GD US Managed access controller Master 838 501 US 838 601 US 1 0 3 Made in the UK ...

Reviews: