The pulse indicator light is not
Check that the energiser is switched on.
flashing.
Ensure the battery is connected correctly with the positive
(red) lead to the positive (+) terminal on the battery and
the negative (black) lead to the negative (–) terminal on the
battery. See “Installing the battery” on page 36.
Replace the battery with a new battery. Before installing a
new battery, charge it fully using a suitable battery charger.
See “Battery charging” on page 40.
If the pulse indicator light is still not flashing, return the ener
giser to a PATURA appointed service agent for repair.
The battery needs frequent
Check that the solar panel is clean and is not damaged.
replacement.
See “Energiser maintenance” on page 40.
Make sure the energiser is positioned to receive maximum
sunlight. If necessary, remove any objects or vegetation that
might be casting a shadow on the energiser.
See “Positioning the energiser” on page 36.
The pulse speed is irregular.
There may be a problem with the energiser. Return the
The pulse indicator light flashes energiser
quickly several times and then
there is a pause (P35 only).
The display on the P50 shows problems with the energiser.
Display shows
Problem
Action
Battery symbol on
The battery is running low.
The energiser may switch to a
(P50 only)
lower pulse speed or power level
setting until the sun has recharged
the battery.
Battery symbol flashing The battery is running very
Check the energiser installation.
(P50 only)
low.
The energiser may not be installed
correctly. Make sure the energiser is
positioned to receive maximum sun
light.
The solar panel may be dirty.
Clean the solar panel.
There may not be sufficient sunlight
- 47 -