background image

7

List of Figures

1

Model 6081RC EdgeRoute Network Access Router  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2

Model 6081RC front panel   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3

Model 6081RC Ethernet port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4

Model 6081RC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

5

Installing the PMC card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

6

Alignment/ESD pin and card handle   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

7

Model 6081RC network and configuration ports  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

8

Ethernet RJ-45 pin and signal definitions for Model 6081RC   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

9

Cross-over RJ-45-to-RJ-45 Ethernet cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

10

DB-9-to-RJ-45 cable diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

11

Connecting the 6081RC to your laptop PC via the Ethernet port   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

12

Connecting the 6081RC to your laptop PC via the console port   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

13

Connecting a serial terminal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

14

Typical Ethernet straight-through cable diagram for 10/100Base-T  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

15

Typical Ethernet straight-through cable diagram for 1000Base-T  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

16

EIA-561 (RJ-45 8-pin) port  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Summary of Contents for EdgeRoute 6081RC

Page 1: ...RC EdgeRoute Network Access Server User Manual Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07MD6081RC GS Rev D Revised Februar...

Page 2: ...rt patton com Copyright 2012 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors that...

Page 3: ...Model 6081RC overview 12 2 Hardware installation 20 3 Initial configuration 28 4 Contacting Patton for assistance 32 A Compliance information 35 B Specifications 38 C Cabling 41 D Port pin outs 44 E...

Page 4: ...18 Power system 18 Central processing unit 18 Temperature 18 Altitude 18 Humidity 18 Physical dimensions 18 Management services 18 LED display 19 2 Hardware installation 20 Introduction 21 Unpacking t...

Page 5: ...33 Warranty Service and Returned Merchandise Authorizations RMAs 33 Warranty coverage 33 Out of warranty service 33 Returns for credit 33 Return for credit policy 34 RMA numbers 34 Shipping instructi...

Page 6: ...le 42 Ethernet 43 D Port pin outs 44 Introduction 45 Console port 45 Ethernet 46 E End user license agreement 47 End User License Agreement 48 1 Definitions 48 2 Title 48 3 Term 48 4 Grant of License...

Page 7: ...et RJ 45 pin and signal definitions for Model 6081RC 26 9 Cross over RJ 45 to RJ 45 Ethernet cable diagram 26 10 DB 9 to RJ 45 cable diagram 27 11 Connecting the 6081RC to your laptop PC via the Ether...

Page 8: ...ist of Tables 1 General conventions 10 2 Mouse conventions 11 3 LED definitions 19 4 Factory default IP address and network mask configuration 30 5 RJ45 socket 10 100Base T 46 6 RJ45 socket 1000Base T...

Page 9: ...is intended for the following users Operators Installers Maintenance technicians Structure This guide contains the following chapters and appendices Chapter 1 describes the Model 6081RC Network Acces...

Page 10: ...follow the warning instructions to avoid personal injury The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard Strictly follow the instructions to avoid property damag...

Page 11: ...on refers the secondary or rightmost mouse button unless you have changed the default configuration Point This word means to move the mouse in such a way that the tip of the pointing arrow on the scre...

Page 12: ...ew 13 Hardware overview 15 LAN Ethernet port 17 Packet switched Ethernet bus PSB 17 Backplane Ethernet interfaces 17 RS 232 control port 18 Power system 18 Central processing unit 18 Temperature 18 Al...

Page 13: ...SLAM functionality to any ForeFront system The Model 6081RC preserves legacy TDM services while providing Layer 2 Layer 3 services TDM data communications can operate seamlessly within the same hardwa...

Page 14: ...ta path backplane service selection based on the capabilities of a module or it s location within a shelf Delivery using Integrated wires through the use of the standard and integrated DACS Now both T...

Page 15: ...used with an external FCAPS NMS Using SNMP management the 6081RC is fully configured managed and monitored via Patton s ForeSight EMS solutions With ForeSight a Graphical User Interface provides an in...

Page 16: ...ole port see figure 2 Three front panel LEDs see figure 2 Two packet switch buss 10 100 Mbps Ethernet ports Optional full termination of TDM chassis bus into 1024 channel HDLC controller Hot swap supp...

Page 17: ...olid yellow at 100 Mbps off at 10 Mbps Figure 3 Model 6081RC Ethernet port LEDs Packet switched Ethernet bus PSB Two internal Ethernet buses connecting over the mid plane for intercard communication w...

Page 18: ...ates of 19 2 kbps 8 data bits no parity 1 stop bit An RJ 45 connector with EIA 561 pinouts A management interface that supports VT 100 terminals Hardware flow control RTS and CTS Power system The Mode...

Page 19: ...up sequence Off No input power is being applied L2 LINK Layer 2 Link Green Flashing The 6081RC is operating properly Off Link has not been established ENET Green On solid Indicates at least one of th...

Page 20: ...ade 22 Model 6081RC blades installation 23 Cable installation 25 Connecting the Ethernet ports 25 Connecting the 10 100Base T Ethernet port to an Ethernet switch or hub 26 Connecting the 10 100Base T...

Page 21: ...he hardware installation on page 27 describes testing the 6081RC hardware to verify that it is ready for software configuration Unpacking the Model 6081RC Inspect the shipping carton for external dama...

Page 22: ...The PMC Ethernet Access Module may be factory installed or you may order it separately for installation in the field The Model 6081RC has two PMC expansion slots numbered 1 and 2 see figure 5 The PMC...

Page 23: ...place Model 6081RC blades installation The Model 6081RC installs in a Patton ForeFront chassis The 6081RC is hot swappable so it is not necessary to power down the chassis before installing the blade...

Page 24: ...The location should be well ventilated Do not block the rack chassis cooling vents 2 Insert the rear blade into the desired slot in the rack chassis Make sure the blade is seated properly in the slot...

Page 25: ...Mbps of the connection and automatically negotiate half or full duplex operation This section describes connecting the front panel Ethernet port on the Model 6081RC to an Ethernet LAN via an Ethernet...

Page 26: ...a straight through CAT 5 cable one wired as shown in figure 8 between the Model 6081RC and the hub switch Figure 8 Ethernet RJ 45 pin and signal definitions for Model 6081RC Connecting the 10 100Base...

Page 27: ...are installation This section verifies that the Model 6081RC hardware is operational to the point where you can begin config uring the software settings Power is delivered from the chassis backplane t...

Page 28: ...ng the 6081RC to your PC 29 Connecting and logging in via the Ethernet port 29 Connecting and logging in via the Console port 30 2 Configuring the desired IP address 30 Factory default IP settings 30...

Page 29: ...equipped with an Auto MDX Ethernet port so you can use straight through cables for host or hub switch connections see figure 11 Figure 11 Connecting the 6081RC to your laptop PC via the Ethernet port...

Page 30: ...t IP settings The factory default configuration for the Ethernet interface IP address and network mask is listed in table 4 The Ethernet interfacee is activated upon power up If this addresse matches...

Page 31: ...ration Trinity copy running config startup config Trinity The 6081RC can now be connected to your network 3 Connecting the 6081RC to the network In general the 6081RC will connect to the network via t...

Page 32: ...r contents Introduction 33 Contact information 33 Warranty Service and Returned Merchandise Authorizations RMAs 33 Warranty coverage 33 Out of warranty service 33 Returns for credit 33 Return for cred...

Page 33: ...ts are carefully tested before ship ment All of our products are backed by a comprehensive warranty program Note If you purchased your equipment from a Patton Electronics reseller ask your reseller ho...

Page 34: ...leting a request on the RMA Request page in the Support section at www patton com By calling 1 301 975 1000 and speaking to a Technical Support Engineer By sending an e mail to returns patton com All...

Page 35: ...liance information Chapter contents Compliance 36 RTTE Directive CE Mark 36 EMC 36 Radio and TV Interference 36 FCC Part 68 ACTA Statement 36 6081RCCE Declaration of Conformity 37 Authorized European...

Page 36: ...anches FCC Part 68 ACTA Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other infor...

Page 37: ...o Radio and Telecommunication Terminal Equipment and the mutual rec ognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed The conformity to the...

Page 38: ...cifications Chapter contents Routing 39 RADIUS client 39 IP Services 39 Ethernet Ports 39 Front Panel Indicators 39 Ethernet Services 40 HDLC Services 40 Management Service 40 Alarm Reporting 40 Safet...

Page 39: ...ng RFC 2866 2867 PAP RFC 1332 CHAP RFC 1334 1994 IP Services ARP RFC0826 Proxy ARP RFC1027 ICMP RFC0950 RFC1256 NTPv3 RFC1305 IGMP IGMPv2 RFC2236 NAT RFC 1631 2663 2766 2993 GRE IPSec AES DES 3DES Eth...

Page 40: ...rvice HTTP SNMP Telnet Ethernet RS 232 Console Port SYSLOG Client Software upgrade via FTP SSH SNTP Alarm Reporting Configurable alarms Remote SNMP Traps Front Panel LEDs Safety UL CSA per UL1950 METS...

Page 41: ...41 Appendix C Cabling Chapter contents Introduction 42 Console 42 Ethernet 43...

Page 42: ...nsole port as depicted in figure 13 Figure 13 Connecting a serial terminal Note See section Console port on page 45 for console port pin outs The interconnecting cables shall be acceptable for externa...

Page 43: ...gh cable diagram for 10 100Base T Figure 15 Typical Ethernet straight through cable diagram for 1000Base T The interconnecting cables shall be acceptable for external use and shall be rated for the pr...

Page 44: ...44 Appendix D Port pin outs Chapter contents Introduction 45 Console port 45 Ethernet 46...

Page 45: ...ut information for the ports of the 6081RC Console port Configuration settings 9600 bps 8 bits no parity 1 stop bit no flow control Figure 16 EIA 561 RJ 45 8 pin port Note N C means no internal electr...

Page 46: ...Server User Manual D Port pin outs Ethernet Note Pins not listed are not used Table 5 RJ45 socket 10 100Base T Pin Signal 1 TX 2 TX 3 RX 6 RX Table 6 RJ45 socket 1000Base T Pin Signal 1 TRD0 2 TRD0 3...

Page 47: ...47 Appendix E End user license agreement Chapter contents End User License Agreement 48 1 Definitions 48 2 Title 48 3 Term 48 4 Grant of License 48 5 Warranty 48 6 Termination 49 7 Other licenses 49...

Page 48: ...the Designated Equipment at a site owned or leased by the End User B The End User may copy licensed Program s as necessary for backup purposes only for use with the Des ignated Equipment that was firs...

Page 49: ...ny may terminate this Agreement should End User violate any of the provi sions of section 4 Grant of License on page 48 C Upon termination for A or B above or the end of the Term End User is required...

Reviews: