High Speed Ethernet Extender

User Manual

This is a Class A device and is not intended for use in a residential environment.

Sales Office:

 

+1 (301) 975-1000

Technical Support:

 

+1 (301) 975-1007

E-mail:

 

[email protected]

WWW:

 

www.patton.com

Part Number: 

07MCL1212-UM, Rev. C

Revised: 

December 12, 2014

Summary of Contents for CopperLink 1211

Page 1: ...User Manual This is a Class A device and is not intended for use in a residential environment Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com...

Page 2: ...free from defects and will at our option repair or replace the product should it fail within one year from the first date of the shipment This warranty is limited to defects in workmanship or materia...

Page 3: ...on 12 2 Installation 15 3 Configuration 20 4 Operation 24 5 Contacting Patton for assistance 26 A Compliance Information 29 B Specifications 32 C Factory Replacement Parts and Accessories 34 D Interfa...

Page 4: ...cting Power 19 3 Configuration 20 Introduction 21 Accessing the DIP Switches 21 Configuring DIP Switch S1 22 Switch S1 1 Local Remote Configuration 22 Switches S1 2 and S1 3 Symmetric Asymmetric Opera...

Page 5: ...s 33 Transmission Line 33 LED Status Indicators 33 Power Supply 33 External AC option 33 Physical 33 Operating Temperature Range 33 Humidity 33 Dimensions 33 C Factory Replacement Parts and Accessorie...

Page 6: ...al Block twisted pair line interface 18 5 CL1212 10 100Base T RJ 45 Connector Pin out 18 6 Removing protective cover 21 7 DIP switch orientation 21 8 CL1212 front panel 25 9 CL1212 10 100Base T RJ 45...

Page 7: ...mote Unit Configuration 22 3 Symmetric Asymmetric Selection Chart 22 4 Signal to Noise Ratio 23 5 Front panel LED description 25 6 Line Rate Reach Chart Using Twisted Pair Long Range 39 7 Line Rate Re...

Page 8: ...ppendix A on page 29 provides compliance information for the CL1212 Appendix B on page 32 provides specifications for the CL1212 Appendix C on page 34 provides a table of replacements for parts and ac...

Page 9: ...the instructions to avoid property damage caused by electric shock WARNING The alert symbol and WARNING heading indicate a poten tial safety hazard Strictly follow the warning instructions to avoid pe...

Page 10: ...ices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wall outlet or socket must have an earth ground For DC powered devices ensure that the interconnecting cab...

Page 11: ...mproperly handled and can result in complete or intermittent failures Do the following to prevent ESD 11 CopperLink 1211 1212 User Manual About This Guide Always follow ESD prevention procedures when...

Page 12: ...12 Chapter 1 General information Chapter contents Features 13 Description 13...

Page 13: ...witch Transparent operation LED indicators for Power Line Local Remote Ethernet 0 and 1 Eth 0 and Eth 1 and Ethernet Link Activity Description Patton Electronics CL1212 Ethernet extenders provide high...

Page 14: ...er Manual 1 General information Figure 1 Typical applications The pair of CL1212 models work together to create a transparent extension between two peered Ethernet LANs using twisted pair 2 wire or Ca...

Page 15: ...contents Planning the Installation 16 Connecting the Line Interface 17 Connecting the Line Interface for CL1212 17 Connecting the Line Interface for CL1212 BNC 18 Connecting the 10 100Base T Ethernet...

Page 16: ...r the CL1212 s rear panel 2 Connect the Ethernet interface refer to Connecting the 10 100Base T Ethernet Interface on page 18 3 Connect the power plug refer to Connecting Power on page 19 S Figure 2 C...

Page 17: ...CL1212 interfaces Note The CL1212 units work in pairs One of the units must be configured as a L Local unit and the other unit must be configured as a R Remote unit Connecting the Line Interface for C...

Page 18: ...shall be acceptable for external use and shall be rated for the proper application with respect to volt age current anticipated temperature flammability and mechanical serviceability The RJ 45 ports l...

Page 19: ...CL1212 does not have a power switch so it powers up as soon as it is plugged in An external AC or DC power supply is available separately This connection is made via the barrel jack on the rear panel...

Page 20: ...ntents Introduction 21 Accessing the DIP Switches 21 Configuring DIP Switch S1 22 Switch S1 1 Local Remote Configuration 22 Switches S1 2 and S1 3 Symmetric Asymmetric Operation 22 Switch S1 5 General...

Page 21: ...Using a small flat tip screwdriver remove the protective cover located on the underside of the CL1212 see figure 6 Figure 6 Removing protective cover 2 The DIP switches are externally accessible from...

Page 22: ...Reserved Switch S1 1 Local Remote Configuration Use switch S1 1 to configure the unit as Remote or Local in the CL1212 pair Table 2 Local Remote Unit Configuration S1 1 Setting ON CPE Remote OFF CO Lo...

Page 23: ...uration Switch S1 5 General Protection Signal to Noise Ratio Use switch S1 5 to configure line noise protection Table 4 Signal to Noise Ratio S1 5 Setting ON 6dB OFF 9dB 6dB Original line noise protec...

Page 24: ...24 Chapter 4 Operation Chapter contents Introduction 25 Front Panel LED Status Monitors 25...

Page 25: ...etting Figure 8 shows the front panel location of each LED Table 5 on page 25 describes the LED functions Line Local Remote Power Eth 0 Eth 1 Figure 8 CL1212 front pan Table 5 Front panel LED descript...

Page 26: ...r contents Introduction 27 Contact information 27 Warranty Service and Returned Merchandise Authorizations RMAs 27 Warranty Coverage 27 Out of Warranty Service 27 Returns for Credit 27 Return for Cred...

Page 27: ...ment All of our products are backed by a comprehensive warranty program Note If you purchased your equipment from a Patton Electronics reseller ask your reseller how you should proceed with warranty...

Page 28: ...uest on the RMA Request page in the Support section at www patton com returns By calling 1 301 975 1007 and speaking to a Technical Support Engineer By sending an e mail to returns patton com All retu...

Page 29: ...rmation Chapter contents Regulatory Information 30 EMC Directive 30 Low Voltage Directive Safety 30 PSTN 30 Radio and TV Interference FCC Part 15 30 CE Declaration of Conformity 30 Authorized European...

Page 30: ...ation If the device does cause interference to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more...

Page 31: ...aid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technic...

Page 32: ...cifications Chapter contents Line Connector 33 LAN Connectors 33 Transmission Line 33 LED Status Indicators 33 Power Supply 33 External AC option 33 Physical 33 Operating Temperature Range 33 Humidity...

Page 33: ...al Green Remote Green Ethernet Green when linked flashing green when transceiving data Power Supply External AC option AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC 5 VDC Power con...

Page 34: ...34 Appendix C Factory Replacement Parts and Accessories Chapter contents CL1211 CL1212 Factory Replacement Parts and Accessories 35...

Page 35: ...h Speed Auto Rate Extender 1 x 10 100Base TX Terminal Block Line Connector 100 240 VAC CL1212 TB EUI CopperLink High Speed Auto Rate Extender 2 x 10 100Base TX Terminal Block Line Connector 100 240 VA...

Page 36: ...36 Appendix D Interface Pin Assignment Chapter contents 10 100Base T Interface 37 RJ 45 37 Line Interface 37 RJ 45 37 Terminal Block 37...

Page 37: ...2 3 4 5 6 7 8 Figure 9 CL1212 10 100Base T RJ 45 Connector Pin out Line Interface RJ 45 1 no connection 2 no connection 3 no connection 4 RING 5 TIP 6 no connection 7 no connection 8 no connection 1...

Page 38: ...38 Appendix E Line Rate Reach Chart Chapter contents Line Rate Reach Chart Based on 24 AWG 0 5 mm 39...

Page 39: ...s to CL1212s with a twisted pair line interface Cl1212 EUl and CL1212 TB Contact Patton for CL1212 BNC rates Table 7 Line Rate Reach Chart Using Twisted Pair High Speed Mode High Speed Distance in Fee...

Reviews: