background image

SmartNode 4900

IpChannel Bank 

User Manual

Sales Office:

 

+1 (301) 975-1000

Technical Support:

 

+1 (301) 975-1007

E-mail:

 

[email protected]

WWW:

 

www.patton.com

Part Number: 

07MSN4900-GS, Rev. I

Revised: 

June 22, 2012

 

Start Installation

For Quick 

Summary of Contents for SMARTNODE 4900

Page 1: ...IpChannel Bank User Manual Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07MSN4900 GS Rev I Revised June 22 2012 Start Installa...

Page 2: ...t is furnished under a license and may be used or copied only in accordance with the terms of such license For information about the license see Appendix E End user license agreement on page 70 or go...

Page 3: ...ion 24 4 Getting started with the SmartNode 4900 Series 36 5 LEDs status and monitoring 46 6 Contacting Patton for assistance 48 A Compliance information 51 B Specifications 55 C Port pin outs 61 D Fa...

Page 4: ...panel 18 SmartNode 4900 Series rear panels 19 Reset button behavior 20 2 Applications overview 21 Introduction 22 SmartNode 4900 Series applications 22 Multiservice carrier access over leased lines 2...

Page 5: ...1 Configure IP address 38 Factory default IP settings 38 Connect to the RS 232 console port 39 Login 40 Changing the WAN IP address 40 2 Connecting the SmartNode to the network 41 3 Loading the confi...

Page 6: ...FXO ports 57 PPP and Frame Relay support 57 Voice processing signaling dependent 57 Fax and modem support 57 Voice signaling 58 Voice routing session router 58 IP services 58 Management 59 Operating...

Page 7: ...le of Contents End User License Agreement 71 1 Definitions 71 2 Title 71 3 Term 71 4 Grant of License 71 5 Warranty 71 6 Termination 72 7 Other licenses 72 F Installation checklist 73 Introduction 74...

Page 8: ...h RJ 45 to RJ 45 Ethernet cable diagram 30 9 Cross over RJ 45 to RJ 45 Ethernet cable diagram 30 10 DB 9 to RJ 45 cable diagram 31 11 IEC 320 connector and grounding stud locations 32 12 Grounding stu...

Page 9: ...s and network mask configuration 38 10 SmartNode LED Indicators 47 11 Rear panel expansion port LEDs 47 12 SmartNode weight and maximum power specifications 59 13 SmartNode Models and their Unique sys...

Page 10: ...ries on page 36 describes getting started with the SmartNode IpChannel Bank Chapter 5 LEDs status and monitoring on page 46 contains definitions for the LED status indicators Chapter 6 Contacting Patt...

Page 11: ...heading calls attention to important information The alert symbol and CAUTION heading indicate a potential hazard Strictly follow the instructions to avoid property damage The shock hazard symbol and...

Page 12: ...s all applicable standards for the coun try in which it is to be installed and that it is connected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardle...

Page 13: ...moist anti static cloth Place the unit on a flat surface and ensure free air circulation Avoid exposing the unit to direct sunlight and other heat sources Protect the unit from moisture vapors and cor...

Page 14: ...ype Parts of commands which are related to elements already named by the user are in boldface italic font Italicized Futura type Variables for which you supply values are in italic font Futura type In...

Page 15: ...eneral information Chapter contents SmartNode 4900 Series overview 16 SmartNode 4900 Series detailed description 17 SmartNode 4900 Series front panel 18 SmartNode 4900 Series rear panels 19 Reset butt...

Page 16: ...se T Ethernet ports from 12 to 32 FXS ports and an integrated optional V 35 or X 21 serial WAN port This provides voice over IP VoIP and Internet telephony integrated with routed serial WAN access The...

Page 17: ...5 or X 21 serial WAN port Ethernet port ETH0 1 is commonly used for the LAN connection ETH0 0 can be used for WAN access or as a second LAN connection The customer s application will determine whether...

Page 18: ...lid green Blinking green Ethernet Port 0 is up Indicates activity ETH1 Solid green Blinking green Ethernet Port 1 is up Indicates activity 20 Green 20 of the voice ports are active 40 Green 40 of the...

Page 19: ...onsole Reset Expansion ETH 0 1 Status Activity 36 72V 1 6 AMP Telco Ports 36 72V 1 6 AMP ETH 0 0 NIC ADDRESS 00 A0 BA 00 04 10 Console Telco Ports Reset Expansion ETH 0 1 Status Activity 36 72V 1 6 AM...

Page 20: ...connects the unit to an Ethernet LAN Expansion V 35 serial port DB 25 connector data rates up to 2 Mbps Frame Relay or PPP protocols Status and Activity LED indicators configured as DTE X 21 serial p...

Page 21: ...overview Chapter contents Introduction 22 SmartNode 4900 Series applications 22 Multiservice carrier access over leased lines 22 Enterprise FXS concentration and extension over IP and T1 E1 23 Bulk a...

Page 22: ...port The two Ethernet ports provide full featured IP routing plus Ethernet and IP layer QoS services The sync serial port provides WAN access for integrated voice and data via a leased line connection...

Page 23: ...rprise network administrators with a simple and cost effective option to provide a large number of FXS ports in a remote location see figure 5 Figure 5 Enterprise FXS concentration and extension over...

Page 24: ...el Bank 28 IpChannel Bank chassis installation 28 Connecting cables 29 Connecting the FXS ports 29 Connecting the FXO ports 29 Connecting the Ethernet ports 30 Connecting the 10 100Base T Ethernet por...

Page 25: ...the device See table 5 for an example of installment checklist that may be necessary for a smoother installation Completing the pre installation checks enables you to install and set up your IpChanne...

Page 26: ...corded in site log Environmental specifications verified Site power voltages verified Installation site pre power check completed Required tools available Additional equipment available All printed do...

Page 27: ...tekeeper if used IP addresses of central PSTN Gateway for H 323 based calls IP addresses of central TFTP Server used for configuration upload and download Configuration tools You will need a PC or equ...

Page 28: ...container contents Report any equipment damage to the shipping carrier immediately for claim purposes Save all packing mate rial in case you need to return an item to the factory for servicing The Ip...

Page 29: ...e cable into the 64 pin or 50 pin RJ 21X receptacle on the IpChannel Bank The pin count will depend on the IpChannel Bank that you ordered 2 The other end of the cable has 25 non terminated twisted pa...

Page 30: ...rnet switch or hub The 10 100Base T Ethernet port is designed to connect to an Ethernet switch or hub with a straight through or cross over Ethernet cable The Ethernet RJ 45 pin and signal definitions...

Page 31: ...al ports see table 8 via a cable terminated at the SmartNode 4900 The V 35 connector is a DB 25 female and the X 21 uses a DB 15 female The sync serial ports are configured as DTE Table 8 Serial port...

Page 32: ...cting to a DC power source see Installing the power cables DC units on page 34 Grounding the Model SN4900 AC and DC units Do the following 1 Assemble a ground wire using 10 AWG wire with green colored...

Page 33: ...rtNode router is equipped with dual power supplies Disconnect both power supply cords before servicing For systems without a power switch line voltages are present within the power supply when the pow...

Page 34: ...rew down terminal block see figure 13 Figure 13 DC connector DC and DC input view 1 Connect the earth ground of the DC source to the grounding stud on the DACS as described in the previ ous section en...

Page 35: ...here are no exposed wires 4 Repeat steps 1 through 3 to install the remaining DC power connection 5 Connect the equipment to a 36 72 VDC 2 5A supply source that is electrically isolated from the AC so...

Page 36: ...he RS 232 console port 39 Login 40 Changing the WAN IP address 40 2 Connecting the SmartNode to the network 41 3 Loading the configuration optional 41 Bootloader 42 Start Bootloader 42 Start up with f...

Page 37: ...he SmartNode to the network 10 0 24 0V 5 0 60 Hz 1 AM P UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE CT BOT H SUP PLI ES BEF OR E SER VIC ING UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE C...

Page 38: ...ing the SmartNode to the net work on page 41 Otherwise refer to the following sections to change the addresses and network masks Table 9 Factory default IP address and network mask configuration IP Ad...

Page 39: ...at supports the serial interface e g HyperTerm Figure 17 Connecting to the RS 232 Console port Terminal emulation program settings Asynchronous 9600 bps No parity 8 bit 1 stop bit No flow control 10 0...

Page 40: ...ip router 192 168 1 1 ctx ip router Now you can set your IP address and network mask for the interface ETH 0 0 WAN Within this example a network 172 16 1 0 24 address is assumed The IP address in this...

Page 41: ...d Summary of the SmartNode Series SmartWare Software Configura tion Guide 3 Loading the configuration optional Patton provides a collection of configuration templates on the support page at www patton...

Page 42: ...ig Press yes to store no to drop changes no Press yes to restart no to cancel yes The system is going down Bootloader The bootloader ensures that basic operations network access and downloads are poss...

Page 43: ...to receive the new application image mask_len is the length of the network address or the number of 1 s within the subnet mask See Note below 2 optional RedBoot ip_address g gateway Sets the IP addre...

Page 44: ...martWare RedBoot ip l 172 16 40 98 19 RedBoot ip g 172 16 32 1 RedBoot ping h 172 16 32 100 Network PING from 172 16 40 98 to 172 16 32 100 PING received 10 of 10 expected RedBoot load r v h 172 16 32...

Page 45: ...ymodem b base_address Downloads an application image into the volatile memory RAM from where the SmartNode could directly execute it xmodem or ymodem Specify the protocol to be used X Modem or Y Mode...

Page 46: ...46 Chapter 5 LEDs status and monitoring Chapter contents Status LEDs 47...

Page 47: ...s the gateway is registered on a gatekeeper media gateway controller associated to a remote unit or has an active VoIP connection Indicates the unit is attempting or has failed to associate or registe...

Page 48: ...r contents Introduction 49 Contact information 49 Warranty Service and Returned Merchandise Authorizations RMAs 49 Warranty coverage 49 Out of warranty service 50 Returns for credit 50 Return for cred...

Page 49: ...75 1007 Alternate Patton support for Europe Middle East and Africa EMEA Online support available at www patton inalp com E mail support e mail sent to support patton inalp com will be answered within...

Page 50: ...be issued upon receipt and inspection of the equipment 30 to 60 days We will add a 20 restocking charge crediting your account with 80 of the purchase price Over 60 days Products will be accepted for...

Page 51: ...ce 52 EMC compliance 52 Safety compliance 52 PSTN Regulatory Compliance 52 Radio and TV interference FCC Part 15 52 CE Declaration of Conformity 52 Authorized European Representative 52 FCC Part 68 AC...

Page 52: ...here is no guarantee that inter ference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the c...

Page 53: ...Authorized European Representative 53 SmartNode 4900 User Manual A Compliance information Watchfield Swindon Wilts SN6 8TD UK...

Page 54: ...commission public service commission or corporation commission for information Industry Canada Notice FXO Ports This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifi...

Page 55: ...e Relay support 56 Voice processing signaling dependent 56 Fax and modem support 56 Voice signaling 57 Voice routing session router 57 IP services 57 Management 58 Operating environment 58 Temperature...

Page 56: ...upporting 100Base TX half full duplex operation 10Base TX half full duplex operation Auto detection and fallback Console port The RS 232 port provides for initial configuration of the Model SN4900 ser...

Page 57: ...ur an encapsulation method created by the four companies Cisco Northern Telecom StrataCom and DEC which differs from the IETF encapsulation PPP PAP CHAP LCP IPCP Voice processing signaling dependent V...

Page 58: ...H 323 Annex M3 SIP SIPv2 RFC3261 RFC3263 SIP call transfer redirect DTMF relay Voice routing session router Local switching Interface huntgroups Routing Criteria Interface Calling called party number...

Page 59: ...re Available in real time on the IpChannel Bank web pages Humidity 5 to 90 relative humidity RH non condensing Altitude Maximum operating altitude 15 000 feet 4 752 meters System The processor is a Mo...

Page 60: ...fication MIB IpChannel Bank 4932 9 1 lb 4 1 kg 50W V 35 or X 21 Serial Card Expansion Port 0 1 lb 45 3 g 1W Table 13 SmartNode Models and their Unique sysObjectID SmartNode Model SysObjectID SN4912 JS...

Page 61: ...61 Appendix C Port pin outs Chapter contents Introduction 61 Console port 61 Ethernet 10Base T and 100Base T port 61 Sync Serial port 62 FXS and FXO ports 63...

Page 62: ...9 EIA 561 RJ 45 8 pin port Note Pins not listed are not used Ethernet 10Base T and 100Base T port Figure 20 Model SN4900 Ethernet port Note Pins not listed are not used 6 DSR 1 CD 4 DTR 5 SG 2 RD driv...

Page 63: ...Description 1 Frame Ground 2 TD a to DCE 3 RD a from DCE 4 RTS to DCE 5 CTS from DCE 6 DSR from DCE 7 Signal Ground 8 CD from DCE 9 RC b from DCE 11 XTC b to DCE 12 TC b from DCE 14 TD b to DCE 15 TC...

Page 64: ...reen Whitee Blue Ring 3 3 White Brown Blue Tip 4 Pair 4 36 Brown White Blue Ring 4 4 White Slate Blue Tip 5 Pair 5 37 Slate White Blue Ring 5 5 Red Blue Blue Tip 6 Pair 6 38 Blue Red Blue Ring 6 6 Red...

Page 65: ...ue Tip 24 Pair 24 56 Brown Purple Blue Ring 24 24 Purple Slate Blue Tip 25 Pair 25 57 Slate Purple Blue Ring 25 25 White Blue Orange Tip 26 Pair 26 58 Blue White Orange Ring 26 26 White Orange Orange...

Page 66: ...ue Tip 6 Pair 6 31 Blue Red Ring 6 6 Red Orange Tip 7 Pair 7 32 Orange Red Ring 7 7 Red Green Tip 8 Pair 8 33 Green Red Ring 8 8 Red Brown Tip 9 Pair 9 34 Brown Red Ring 9 9 Red Slate Tip 10 Pair 10 3...

Page 67: ...21 46 Blue Violet Ring 21 21 Violet Orange Tip 22 Pair 22 47 Orange Violet Ring 22 22 Violet Green Tip 23 Pair 23 48 Green Violet Ring 23 23 Violet Brown Tip 24 Pair 24 49 Brown Violet Ring 24 24 Viol...

Page 68: ...68 Appendix D Factory Configuration Chapter contents Introduction 68...

Page 69: ...network 192 168 1 0 255 255 255 0 include 1 192 168 1 10 192 168 1 99 lease 2 hours default router 1 192 168 1 1 domain name server 1 192 168 1 1 context ip router interface eth0 ipaddress dhcp use p...

Page 70: ...70 Appendix E End user license agreement Chapter contents End User License Agreement 70 1 Definitions 70 2 Title 70 3 Term 70 4 Grant of License 70 5 Warranty 70 6 Termination 71 7 Other licenses 71...

Page 71: ...ated Equipment at a site owned or leased by the End User B The End User may copy licensed Program s as necessary for backup purposes only for use with the Des ignated Equipment that was first purchase...

Page 72: ...te this Agreement should End User violate any of the provi sions of section 4 Grant of License on page 71 C Upon termination for A or B above or the end of the Term End User is required to destroy all...

Page 73: ...73 Appendix F Installation checklist Chapter contents Introduction 73...

Page 74: ...tion checklist Task Verified by Date Network information available recorded in site log Environmental specifications verified Site power voltages verified Installation site pre power check completed R...

Page 75: ...75 Appendix G Accessories Chapter contents Introduction 75...

Page 76: ...o DB 15 male cable Sync serial X 21 port EMEM216006 64 pin telco to open end cable 6 ft 1 8 m 64 pin FSX port 10493264 10 50 pin telco to open end cable 20 ft 6 m 10 3096TM50 20 50 pin telco 16 ends R...

Reviews: