background image

USER
MANUAL

MODEL 3P-MF and
3P-MF9

DB-25 and DB-9
In-Line Power
Supply Adapters 

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007

Part# 07M3PMF9 Rev. 

C

Doc# 056020U
Revised 

1/23/08

An ISO-9001

Certi

Þ

ed Company

Summary of Contents for 3P-MF

Page 1: ...NUAL MODEL 3P MF and 3P MF9 DB 25 and DB 9 In Line Power Supply Adapters SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M3PMF9 Rev C Doc 056020U Revised 1 23 08 An ISO 9001 Certi ed C...

Page 2: ...erence 2 1 2 CE Notice 2 1 3 Service 3 2 0 General Information 4 2 1 Features 4 2 2 Description 4 3 0 Installation 5 A Patton Model 3P MF 3P MF9 Specifications 6 A 1 Transmission Format 6 B Patton Mod...

Page 3: ...that is in strict accor dance with the manufacturer s instructions may cause interference to radio and television reception The Models 3P MF and 3P MF9 have been tested and found to comply with the l...

Page 4: ...r This number may be obtained from Patton Electronics Technical Service at 301 975 1007 http www patton com or support patton com Note Packages received without an RMA number will not be accepted Patt...

Page 5: ...LED indicator shows power status 120 or 230 VAC versions available Very thin case 0 7 in 1 8 cm for closely spaced computer ports Nothing to con gure just plug it in 2 2 DESCRIPTION The Model 3P MF Se...

Page 6: ...he low power EIA 232 device 2 Connect Model 3P MF 3P MF9 into the DB 25 DB 9 connector of the short haul modem 3 Connect the other end of the 3P MF 3P MF9 into the EIA 232 device The application shoul...

Page 7: ...DB 25M and DB 25F Model 3P MF9P DB 9M and DB 9F A 6 POWER SUPPLY 120 or 230 VAC wall mount adapter supplies 9 VDC A 7 MAX POWER OUTPUT 9 VDC 5 at 100mA approx 945 mW A 8 SIZE Model 3P MF9 2 7 x 1 2 x...

Page 8: ...Data 14 Transmit Clock 15 Secondary Receive Clock 16 Receiver Clock 17 Local Loopback 18 Secondary Request to Send 19 Data Terminal Ready 20 Remote Loopback 21 Ring Indicator 22 Data Signal Rate Sele...

Page 9: ...8 APPENDIX C PATTON MODEL 3P MF BLOCK DIAGRAM...

Page 10: ...h pin 9 default setting DSR or RTS by changing jumper settings see Table 1 Table 1 Power Output Strap Selection Jumper Description JP 1 Connect 9 VDC to male connector Default setting JP 2 Connect 9 V...

Page 11: ...r prod uct needs today and in the future We are committed to a quality product at a quality price Patton Electron ics is ISO 9001 certi ed We meet and exceed the highest standards in the industry CE U...

Page 12: ..._________________________________________ _________________________________________________________ _________________________________________________________ __________________________________________...