USER
MANUAL

MODEL 1089/I

10BaseT HDSL Rocket

Part# 07M1089I-UM
Doc# 03207U2-001,
Rev. D
Revised 10/25/06

SALES OFFICE
(301)975-1000
TECHNICAL SUPPORT
(301)975-1007
http://www.patton.com

An ISO-9001

Certified

Company

Summary of Contents for 1089/I

Page 1: ...MANUAL MODEL 1089 I 10BaseT HDSL Rocket Part 07M1089I UM Doc 03207U2 001 Rev D Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 Certified Comp...

Page 2: ...not limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all...

Page 3: ...Point Connectivity over 2 Wire HDSL up to 5km HTTP SNMP Manageable as CP Customer Premises Unit with 1094ARC CO Central Office Rack Card Internal or receive recovered clocking between units LED indic...

Page 4: ...1 shows a typical Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote E...

Page 5: ...the table below Switch S2 1 S2 2 S2 3 S2 4 S2 5 and S2 8 Switches S2 1 S2 2 S2 3 S2 4 S2 5 and S2 8 are reserved for fac tory use and must remain in the factory default settings as shown in the table...

Page 6: ...d S3 1 S3 2 S3 3 S3 4 S3 5 S3 6 DTE Rate kbps Off Off On On On On 64 On On Off On On On 128 Off On Off On On On 192 On Off Off On On On 256 Off Off Off On On On 320 On On On Off On On 384 Off On On Of...

Page 7: ...nfigured as DTE Data Terminal Equipment If the Model 1089 is to to connect to another DTE device such as a 10Base T network interface card construct a 10Base T crossover cable and connect the wires as...

Page 8: ...Section 5 4 and ensure that the unit will be connected to the appropriate power source 6 2 LED STATUS MONITORS The Model 1089 features six front panel LEDs that monitor con nections on the DSL and 10B...

Page 9: ...eak G GREEN O ORANGE on ON of OFF F Flashing G Green if a valid 10Base T connection is detected 15 6 4 TEST MODES The Model 1089 offers a proprietary Remote Loopback test modes plus a built in V 52 BE...

Page 10: ...o establish a new line connection The rea son that there are different Restart Times will become apparent after reading the rest of the document The 511 511E Time Out shown refers to the amount of tim...

Page 11: ...ern The ER led will begin blinking until the user turns off the 511 511E switch 6 4 3 Using the V 52 BER Test Pattern Generator To use the V 52 BER tests in conjunction with the Remote Digital Loopbac...

Page 12: ...res Line Coding CAP Carrierless Amplitude and Phase Modulation Line Rates DSL line 144 272 400 528 784 1040 1552 2064 2320 kbps Line Interface Transformer coupled 1500 VAC isolation mDSL Physical ETHE...

Page 13: ...1040 832 896 960 1024 11900 2 3 3 6 15500 2 9 4 6 1168 1088 1152 11000 2 1 3 3 15200 2 8 4 4 Line Rate DTE Rates kbps feet miles km feet miles km 144 64 128 18600 3 5 5 6 22100 4 2 6 7 272 192 256 15...