background image

 

Patron Lasers 

      Tattoo 

removal 

 

    O P E R A T O R ’ S       

M A N U A L

Summary of Contents for T8

Page 1: ...Patron Lasers Tattoo removal O P E R A T O R S M A N U A L...

Page 2: ...fety 3 1 2 EYE protective 3 1 3 Physician Responsibility 4 1 4 Maintenance 4 1 5 Modification of the System 4 1 6 Abbreviations and Acronyms 4 CHAPTER 2 7 2 Product Description 8 2 1 Introduction 8 2...

Page 3: ...ntrol and Program 22 5 3 1 Control panel 22 5 3 2 Requirements for operators 23 5 3 3 According to the control panel and buttons function 23 CHAPTER 6 25 6 Operation steps 26 6 1 Steps 26 6 1 1 starti...

Page 4: ...9 7 4 Treatment times 29 7 5 Preoperative considerations 29 7 6 Postoperative considerations 30 CHAPTER 8 31 8 Tattoo matters 32 CHAPTER 9 33 9 Maintenance and precautions 34 9 1 Precautions and instr...

Page 5: ...1 1 Use of this manual 2 1 1 Laser safety 2 1 1 1 Device safety 2 1 1 2 Therapy and its fire safety 3 1 2 EYE protective 3 1 3 Physician Responsibility 4 1 4 Maintenance 4 1 5 Modification of the Sys...

Page 6: ...exports and at the end of the laser beam reflected 2 Laser window should not work with the instrument chassis or display avoid laser damage to casing and display 3 In addition to the affected area for...

Page 7: ...educe the operator in the treatment of visual fatigue 6 In order to prevent the accident injury to the eye laser operation the healer laser protective goggles must be worn during treatment patients mu...

Page 8: ...on of the device and for all operator qualifications The physician is responsible for contacting his or her local licensing agencies to determine any credential required by law for clinical use and th...

Page 9: ...er s CW Continuous wave Hz Hertz IEC International Electro Technical Commission J Joule s J cm2 Joule s per square centimeter Kg Kilogram s Lbs Pound s LCD Liquid crystal display LED Light emitting di...

Page 10: ...6 Rep Rate Repetition rate Sec Second s SPF Skin protection factor TEC Thermoelectric cooling V Volt s VAC Volt s AC W Watt s...

Page 11: ...7 CHAPTER 2 Chapter Contents CHAPTER 2 7 2 Product Description 8 2 1 Introduction 8 2 2 Appearance and part name 9 2 3 Service panel 11...

Page 12: ...ms In the process of laser xenon lamp in the light of have a large amount of heat produced After water circulating system will be hot Commonly known as the light arm joint arm Laser smooth is converge...

Page 13: ...light arms appropriately adjust the way as the center of rotation of the adjustment block fixed nut Prohibit unauthorized users open the equipment side platens and remove the internal components 2 2 A...

Page 14: ...10...

Page 15: ...11 2 3 Service panel Power Cable Inlet Leakage protection Fill and Drain port Vent port Footswitch Connection...

Page 16: ...12 CHAPTER 3 Chapter Contents CHAPTER 3 12 3 Treatment principle 13...

Page 17: ...t like particles Because the particles are so small they are more readily absorbed and eliminated by the body This can mean better clearance of the melanin and less treatments overall This machine is...

Page 18: ...14...

Page 19: ...15 CHAPTER 4 Chapter Contents CHAPTER 4 15 4 Technical parameters 16...

Page 20: ...532nm Width of Pulse 2 6ns Pulse Energy 1000mj 1064nm 500mj 532nm Genesis Mode 4500mj PTP Mode 50 Energy Increasing Repetition Up to 10Hz Spot Size 2 10mm Light transmission way 7 Joints arm import f...

Page 21: ...17 CHAPTER 5 Chapter Contents CHAPTER 5 17 5 Program and Installation 18 5 1 Installation 18 5 2 Fill and Drain 19 5 2 1 Water Filling Procedure 20 5 2 2 Water Draining Procedure 21...

Page 22: ...ttention to the following parts carefully unwrapped the package and put the instrument in primary position choose good equipment install the host was laid Remove the other necessary components and ins...

Page 23: ...Fill and Drain Fill port and Drain port Vents port TIPS For this machine the fill port and the Drain port is the same one Therefore filling water and discharging water must be completed through this o...

Page 24: ...the clear tubing with the service panel see Figure Stop filling as soon as the water starts to spill from the Vent port 3 Plug in the main power supply cable 4 Connect the desired module to the syste...

Page 25: ...ining is required when the system needs to be moved or shipped away particularly in cold weather to avoid freezing hazards 1 Place a shallow container and locate it adjacent to the service panel 2 Con...

Page 26: ...22 5 3 Control and Program 5 3 1 Control panel Key Switch Signal line Light guide arm Control screen Emergency stop Key Switch...

Page 27: ...rs Instrument of the operator should know the professional knowledge medical laser by using after training qualified professional staff 5 3 3 According to the control panel and buttons function LCD sc...

Page 28: ...laser energy 3 Frequency Hz Used to adjust the pulse laser output frequency 4 Facula mm 2 10mm adjust 5 PULSE COUNT Used to record the number of pulse output 6 WAVELENGTH 1064 and 532 wavelengths 7 SI...

Page 29: ...25 CHAPTER 6 Chapter Contents CHAPTER 6 25 6 Operation steps 26 6 1 Steps 26 6 1 1 starting 26 6 1 2 treatment 26 6 1 3 power off 26...

Page 30: ...e energy stepped on the foot switch instrument started out the light 6 1 2 treatment Aim the joint arm output port is needed treatment the control output port and distance treatment parts of the joint...

Page 31: ...8 7 1 Treatment Area 28 7 2 Advantage 28 7 2 1 High Tech 28 7 2 2 Fast Effective 28 7 2 3 Comfortable Safe 28 7 2 4 No melanin precipitate 28 7 3 Treatment of interval 29 7 4 Treatment times 29 7 5 Pr...

Page 32: ...ng treatment 7 2 2 Fast Effective Q Laser Lumius machine make tattoo pigment removal treatment process from 5 to 10 times reduced to 2 to 4 times greatly reduce the treatment and recovery time with fa...

Page 33: ...ment using laser doses patient s body macrophages to factors such as the absorption of pigment particles are decided Exogenous pigment must be more than 3 times treatment commonly endogenous pigment m...

Page 34: ...appear even purpura can absorb itself need not too nervous 1 If there is scabby 7 14 days to fall off avoid by all means remove so as not to delay the healing and the formation of pigmentation of the...

Page 35: ...31 CHAPTER 8 Chapter Contents CHAPTER 8 31 8 Tattoo matters 32...

Page 36: ...cars after burn and ointment 3 For some containing metal ions such as iron ion pigment can appear after laser irradiation is not easy to be absorbed in black chemicals such as ferrous oxide color burn...

Page 37: ...33 CHAPTER 9 Chapter Contents CHAPTER 9 33 9 Maintenance and precautions 34 9 1 Precautions and instructions 34 9 2 Maintenance and repair 35...

Page 38: ...ct safety protection 3 laser therapeutic apparatus is the skin with integration of optical mechanical and electrical precision instruments As a result the operator must be trained The trained personne...

Page 39: ...or and microelectronic devices The maintenance and repair should be consistent with precision optics and microelectronics the general provisions of the instrument Storage and use of carefully knock ag...

Page 40: ...36 CHAPTER 10 Chapter Contents CHAPTER 10 36 10 Product configuration list 37...

Page 41: ...37 10 Product configuration list Host machine one Laser Joint arm one Foot switch one Power line one Laser protect glasses one Eye Glasses one...

Reviews: