ASSEMBLY INSTRUCTIONS (continued)

5. With silicone caulking compound

    (not included), caulk completely 

    around where the backplate of the

    fixture (A) meets the wall surface.

    CAUTION: Be sure to caulk 

    completely where the backplate

    meets the wall surface to 

    prevent water from seeping into

    the light fixture (A) and outlet box. 

 

Controls

Backplate

For eave mounted only:

Swing the sensor head towards the mounting bracket.

Rotate the sensor head clockwise 180˚ so the controls face down.

Turn off the power at fuse or circuit box.

Installation Steps

1. Install the mounting strap (BB) to 

    the outlet box with the stamped 

    word “FRONT” facing away from 

    the outlet box, using two mounting

    screws (AA) that best fit the outlet 

    box. (Choose one matching pair of

    suitable mounting screws from the

    3 pairs provided)

5

3

3. Connect the house grounding wire

    and the fixture grounding wire

    (green) using the wire

    connector (CC).

    Connect the fixture black wire to

    the house black wire and the fixture

    white wire to the house white wire 

    using wire connector (CC) provided.

    Carefully tuck the wires back into the outlet box.

Adjusting the Sensor Head: 

1. a: Aim sensor head (C) toward desired detection area, maintaining a 5° - 40° 

        downward angle to allow moisture to drain.

        Note: Make sure sensor head is positioned with control knob facing towards the 

        ground.

    b: You can rotate the sensor head up and down to change the coverage area. 

        (See Fig.1) 

2. Note: Range set too high may increase false triggering. (See Fig.2, Fig.3) 

2. Thread the fixture wires through 

    gasket (DD), then attach the 

    gasket (DD) into backplate of the 

    fixture (A).

4. Attach the backplate of the light 

    fixture (A) to the mounting strap

    (BB), then secure it with the fixture

    mounting screw (FF). Push the

    decorative cover (EE) firmly into 

    the fixture mounting screw hole

    on the light fixture (A).

 

    

   

Fig. 1

Sensor Adjustment Lower For Short Coverage

Sensor Adjustment Higher For Long Coverage

Fig. 2

Fig. 3

C

A

Controls

Controls

1

BB

AA

Outlet Box

A

2

DD

CC

Page 3 of 7

201015

 

4

EE

FF

BB A

Summary of Contents for E9201-2BZ

Page 1: ...m 5 00 p m CST PACKAGE CONTENTS SKU Number 356 9428 356 9429 2 LIGHT OUTDOOR SECURITY LIGHT Model Number E9201 2BZ E9201 1WH HARDWARE CONTENTS Note Hardware not shown actual size Page 1 of 7 201015 A...

Page 2: ...out your local codes permits and or inspections Risk of fire most dwellings built before 1985 have supply wire rated for 140 F 60 C Consult a qualified electrician before installation Do not connect t...

Page 3: ...C Connect the fixture black wire to the house black wire and the fixture white wire to the house white wire using wire connector CC provided Carefully tuck the wires back into the outlet box Adjusting...

Page 4: ...as long as the motion continues Then it reverts back to low level brightness 2700K about 5 seconds after motion is no longer detected 2 OFF MODE nighttime operation only In OFF mode slide the Time De...

Page 5: ...s on all night long To shift back to OFF or AUTO or 3H mode turn the wall switch OFF then turn it ON twice within 3 seconds again See Fig 6 The light turns off automatically at dawn Note To make sure...

Page 6: ...ht switch on Replace the fuse or turn the circuit breaker on Recheck after dark Verify the wiring is correct Re aim the motion sensor to cover the desired area Increase the SENS setting Daylight turn...

Page 7: ...r on and off The motion sensor is in TEST mode and warming up Reposition the lamp heads away from the motion sensor Decrease the SENS setting or reposition the motion sensor While in TEST mode the lig...

Reviews: