-29 -
PATON
StandardMIG
MMA/TIG/MIG/MAG
a) 0[OFF] ... 80% (increment 1%)
3) [Fr.P] voltage pulsing frequency = 20Hz (by default)
a) 5 ... 500Hz (increment 1Hz)
4) [dut] mark‐to‐space ratio (duty ratio) is the ratio of larger voltage cycle to pulse
spacing in percent = 50% (by default)
a) 20 ... 80% (increment 1%)
On the right wire feeder indicator:
0) [-1-] main displayed parameter FEED SPEED = 7.0m/min (by default)
a) 2.0 ... 16.0m/min (increment 0.1m/min)
1) [But] torch button mode = [2T] (by default)
a) [2t] – torch button mode 2Т
b) [4t] – standard torch button mode 4Т
c) [_4t] – alternate torch button mode 4Т
2) [t.Pr] pre‐purging with shielding gas time = 0.5s (by default)
а) 0.1 ... 25.0s (increment 0.1s)
3) [t.P0] post‐purging with shielding gas time = 1.5s (by default)
a) 0.1 ... 25.0s (increment 0.1s)
4) [t.uP] wire‐feeding speed fade‐in time = 0.1s (by default)
a) 0.1 ... 5.0s (increment 0.1s)
5) [t.dn] wire‐feeding speed fade‐out time = 0.1s (by default)
a) 0.1 ... 5.0s (increment 0.1s)
8. GENERATOR OPERATION MODE
The power source can be operated from a generator upon the following condition:
When
working with
electrode
Set current
value in MMA
and TIG modes
When working with wire
of specified diameter in
MIG/MAG mode
Minimum
generator
power
Ф
2
80А at most
Ф
0.6mm at most
2.9kVA
Ф3
120А at most
Ф
0.8mm at most
4.5kVA
Ф
4
160А at most
Ф
1.0mm at most
6.2kVA
Ф
5
200А at most
8.0kVA
Ф
6, low-
melting
250А at most
Ф
1.2mm at most
11.0kVA