These parameters are set in different situations in different ways, according to
the requirements of the welder. See Clause 6.1 for sequence of changing the value
of any function in the current welding mode.
6. MACHINE SETTING
If buttons on the front panel are not touched, the machine always displays the
value of the main parameter of the current welding mode on the left of its digital
indicator:
1) in MMA mode – arc current;
2) in TIG mode – arc current;
3) in MIG/MAG mode – arc voltage.
The value of the wire‐feeding speed in “m/min” is displayed on the right side
of the digital indicator in MIG/MAG mode.
Button
5
on the front panel of the machine is responsible for selecting the
source function in the current welding mode, and button
10
—for selecting the
function of the wire‐feeding machine in MIG/MAG mode; this will be discussed in
Clause 6.1.
Button
6
on the front panel of the machine is responsible for selecting the
welding mode; this will be discussed in Clause 6.2.
Buttons
1
on the front panel of the source is responsible for changing the
current value on the digital display on the left.
Button
12
on the front panel of the wire‐feeding machine is responsible for
changing the current value on the digital display on the right side.
6.1 SWITCHING TO THE REQUIRED FUNCTION
If the machine has a system of protection against unauthorized access to the
function menu, then pressing the button
5
on the source on the indicator on the
left does not make any changes, that is, this button is locked. In order to unlock it,
it is necessary to keep it pressed for more than 3.5 seconds. When unlocked, the
indicator will display horizontal bars indicating that the function menu is unlocked.
After successful unlocking, when the button
5
is pressed, the digital indicator
displays the graphic name of the current function of the power source of the
welding arc and while it is held down, it can be viewed. After releasing the button,
the current value of this function is displayed on the screen, which can be changed
down or up using buttons
1
. With a quick press and release of the button
5
, you can
switch to the next function over end‐around.