PATON
PRO-315
MMA/TIG/MIG/MAG
-26 -
8. GENERATOR OPERATING MODE
The power source is suitable for operation from the generator provided:
When
working with
an electrode
Current set at
MMA and TIG
When working with wire
diameter
at MIG/MAG
Minimum
generator
power
Ø
2
not more than
80А
not more than
Ø
0.6 mm
2.9 kVA
Ø 3
not more than
120A
not more than
Ø
0.8 mm
4.5 kVA
Ø
4
not more than
160А
not more than
Ø
1.0 mm
6.2 kVA
Ø
5
not more than
220А
9.0 kVA
Ø
6 easily
melted
not more than
250 А
not more than
Ø
1.2 mm
10.7 kVA
Ø
6
not more than
315А
not more than
Ø
1.4 mm
13.5 kVA
For trouble free operation!
The output phase-to-phase voltage of a three-phase
generator should not exceed the allowable limits of 320-440 V.
9. CARE AND MAINTENANCE
Warning!
Before you open the machine for preventive maintenance, you must
turn it off and unplug the mains plug from the outlet. To enable the internal circuits
of the machine to discharge (approximately 5 minutes) and only after that do the
remaining actions. When leaving, you need to install a sign prohibiting the turning
on.
In order to keep the machine operational for many years, you must follow a
few rules:
-
to make safety inspections at specified intervals (see section “Safety rules”);
-
at intensive using, we recommend to blow the device with dry compressed air
every six months.
Warning!
Blowing from too short distance may damage the
electronic components;
-
If there is a lot of dust, clean the cooling system channels by hand.
10. STORAGE RULES
The deactivated and packaged source should be stored in storage conditions 4
according to GOST 15150-69 for a period of 5 years.