62
63
Wall mount Signal Tower Instruction Manual
8. Operation
8.3.2. Get HTTP command status
By sending HTTP command, you can check the Signal Tower and buzzer status, and also the software version.
Item
Description
Protocol
HTTP
Method
GET
Syntax
http://<IPaddress>/api/status?<parameter_name>=<value>
Response
Response data in text and
JSON format
When the parameter name is correct.
Error.
When the parameter name is incorrect.
Parameter
Name
Parameter
Values
Description
format
format = <string>
text, json
Returns the current status of the Signal Tower in the specified format.
text: data in text format, json: data in JSON format
Specify the pattern in this order: Tier 1, Tier 2, Tier 3, Tier 4, Buzzer
●
Available data
Item
Header
Description
Data type
(JSON format)
Status of Signal
Tower Control
Status1 to 5
Indicates the control status (pattern) of the Signal
Tower.
*1
(Decimal)
Light color
Information
Color1 to 5
Indicates Signal Tower light color information.
*2
String
Buzzer control state
Buzzer Pattern
Indicates buzzer control status.
(Decimal)
Main unit firmware
Firmware Version
Indicates the firmware version.
□
.
□
□
↑
0-9
String
MAC Address
MAC Address
Indicates the MAC address of this product.
□
:
□
:
□
:
□
:
□
:
□
↑
00H-ff H
String
*1 Status5 is 0 (fixed).