46
Wireless Data Communication System - WD PRO Series Instruction Manual
8. Function Details
8.1.2 Remote Control Functions
Remote Control Functions*
2
uses specific commands from the host to perform remote control of LED or buzzer units.
Control is possible when receiving specific commands from the host. These functions operate with a higher priority
than Signal Tower Control Functions.
LED unit control
Control the following states individually for each color.
Light on/Flashing/Light off/Triple flash*
1
/control from Signal Tower control line
Buzzer unit control
Buzzer on/Continuous*
3
/Buzzer off/control from Signal Tower control line
Control Status Response
When a specific command is received from the host, response command that includes the
status of the LED unit or buzzer unit that is under remote control.
* 1 Triple flash does not work on LR6-E-MZ.
* 2 Cannot use with WDS-WIN01.
* 3 When using continuous buzzer to control the buzzer unit, set the buzzer pattern to [Continuous beep].
Signal Tower
Control Line
Based on the control
instruction, change to
the specified color and
buzzer status
WDB-D80S \
WDT-PRO
Host PC
Control Instruction
・
Control on/off
・
Status of each color+buzzer
NOTICE
●The operation status of LED and buzzer units, controlled with remote control functions from the host, is not transmitted
back to the host as Signal Tower information as the control is not carried out by Signal Tower control inputs.
●While LED and buzzer units are controlled with remote control functions from the host, and inputs change on the Signal
Tower control line, that Signal Tower information is transmitted to the host.