4.9. Mirroring Setup
This section explains how to configure Mirroring settings.
[Mirroring Source Settings]
1 Attach the lead wires.
2 Attach the LAN cable.
3 Display the "Main Unit Setup" screen.
"4.9.1. Setting up the Mirroring Source"
on page 29
4 Set to the "Signal Wire Control".
5 Display the "Mirroring Set up" screen.
6 Register the IP address of mirroring destination.
[Mirroring Destination Point Settings]
1 Attach the LAN cable.
2 Display the "Main Unit Setup"
screen
.
"4.9.2. Setup Mirroring Destination
Point" on page 30
3 Set to the "Command Control".
・・・
Mirroring original signal
line control method
Mirroring information update
Mirroring destination
command control method
(Maximum: 8 LA6-PoE)
on Status Change
Up
to nine
LA6-POE Signal Towers can be in the same status by sending the status of the LA6-POE which is being
controlled by the Master via the signal line, to another
one of eight
LA6-POE Signal Towers connected within the network.
The maximum possible number of mirrored LA6-POE Signal Towers is
eight units
.
Mirroring information is updated when the status changes.
Even if status does not change, the mirroring information is updated every 10 seconds.