20
Signal Tower LA6-POE Operation Manual
4.4. LED Unit Setup
This product can control the Signal Tower in two modes, Signal Tower mode and smart mode.
■
Signal Tower Mode
It is a mode to set the tone color of each LED tier and buzzer in advance for this product and control it by the signal line
and commands.
■
Smart Mode
There are three types for the Smart Mode, "Time Trigger Type", "Pulse Trigger Type", and "Single Display Type":
• Time Trigger Type
The pattern transitions can be controlled in accordance to time.
• Pulse Trigger Type
The pattern transitions can be controlled in accordance to the trigger input.
• Single Display Type
The registered pattern is executed.
In each mode, every motion pattern is set in advance for this product and the pattern is executed in accordance to the
signal line and command settings.
There are two ways to set up this product, writing and loading data that was set up, or using Web settings.
4.4.1. Loading Setup Data
The LED unit can be Setup from the “EDITOR for LA series”. The set data can be written from the "Configuration" screen.
* For the Setup method, refer to the help section in the “EDITOR for LA series”.
[Data writing method in Web Setting]
In "Write LED Unit Setup Data", the data is selected in the “EDITOR for LA series”.
The "Write" button is clicked to update the LED unit Settings. It reboots automatically after updating.