Pasport PS-2190 Instruction Sheet Download Page 1

®

I n s t r u c t i o n   S h e e t

0 12 - 1 02 5 3 A

1 MHz 2-channel Voltage Sensor

PS-2190

Included Equipment

1 MHz 2-channel Voltage Sensor

Additional Equipment Required

Xplorer GLX datalogger (PS-2002)

Patch Cords (SE-9750 or SE-9751)

Quick Start

1.

Connect the 1 MHz 2-channel Voltage Sensor to your 
PASPORT Xplorer GLX datalogger.

2.

Use patch cords to connect Channel 1 and Channel 2 to the 
parts of the circuit for which you want to measure the volt-
age. 

3.

On the Xplorer GLX, press the start button (

s

) to begin 

recording data.

4.

When data recording is done, press the start button again to 
stop recording data. 

The sensor measures up to two voltages simultaneously at speeds 
up to one million samples per second when used with the GLX in 
oscilloscope mode. 

Introduction

The 1 MHz 2-channel Voltage Sensor is a high speed, two chan-
nel PASPORT voltage sensor that has a basic voltage range of 
±10 volts. It has amplifiers that allow full-scale input ranges of 
±1 volt and ±0.1 volt. The sensor uses an oversampling scheme 
that allows input sampling at speeds up to one million samples 
per second.

The 1 MHz 2-channel Voltage Sensor connects to a PASPORT 
Xplorer GLX datalogger. Measurements are recorded and dis-
played by the datalogger.

Set-up

Connecting the Sensor to an Xplorer GLX 
Datalogger

Plug the sensor into any port on the top of the PASPORT Xplorer 
GLX datalogger. The Xplorer GLX screen will automatically 
show a Graph display of voltage versus time. 

Setting Sensor Parameters

Sample rate, data averaging, and input voltage range are set in the 
Sensors screen.

Press the Home button (

h

) to open the Home screen.

Press  F4  (

I

) under Sensors in the Home screen to open 

the Sensors screen. 

Figure 1: Sensor screen

Summary of Contents for PS-2190

Page 1: ...uction The 1 MHz 2 channel Voltage Sensor is a high speed two chan nel PASPORT voltage sensor that has a basic voltage range of 10 volts It has amplifiers that allow full scale input ranges of 1 volt and 0 1 volt The sensor uses an oversampling scheme that allows input sampling at speeds up to one million samples per second The 1 MHz 2 channel Voltage Sensor connects to a PASPORT Xplorer GLX datal...

Page 2: ...ice and then press the check button to select the choice and close the menu The input voltage range for each channel can be set indepen dently Selecting Scope Mode The 1 MHz 2 channel Voltage Sensor is designed to be used with the Xplorer GLX in Scope Mode where the maximum sample rate of 1 000 000 Hz can be selected Press the Home button to open the Home screen Press the F1 button F under Graph t...

Page 3: ...led When the Trigger is Enabled an arrow appears along the vertical axis at the Trigger Level For Trigger Level press the check button to highlight the numeric value and use the alphanumeric key pad to enter a new value and then press c again Press the F1 F button to select OK or the F2 G button to select Cancel Trigger in the Graph Display The Trigger can be used in normal graph mode to start con...

Page 4: ...ght The PASCO scientific 012 10253A 1 MHz 2 channel Voltage Sensor Instruction Sheet is copyrighted with all rights reserved Permission is granted to non profit educational institutions for reproduction of any part of this manual providing the reproductions are used only in their laboratories and classrooms and are not sold for profit Reproduction under any other circumstances without the written ...

Reviews: