Pasport PS-2170 Instruction Manual Download Page 1

®

I n s t r u c t i o n   M a n u a l

01 2- 095 23 A

Chemistry MultiMeasure Sensor

PS-2170

5

10

15

20

25

30

35

40

45

50

55

60

cc

2

3

4

5

6

7

8

CHEMISTR

Y

PS-2170

ä

SENSOR

PRESSURE

pH/ISE/ORP

VOLTA

GE

TEMPERA

TURE

1

Included Equipment

Part Number

1. Chemistry MultiMeasure Sensor

PS-2170

2. Stainless Steel Temperature Probe

PS-2153

3. Voltage Probe

PS-2165

4. pH Electrode

699-195

5. Polyurethane Tubing (60 cm long, 

 inch ID) 640-023

6. Quick-release Connectors (qty. 4)

640-021

7. Tubing Connectors (qty. 4)

640-030

8. Syringe (60 cc)

699-166

Required Equipment

PASPORT Interface

1

1

PASPORT interfaces include the AirLink (IW-4100 or PS-2005), Xplorer GLX (PS-2002), Xplorer 

(PS-2000), PowerLink (PS-2001), and USB Link (PS-2100)

See PASCO catalog or 

www.pasco.com

Optional Equipment

Fast-response Temperature Probe

PS-2135 (3-pack)

Skin/surface Temperature Probe

PS-2131

Various Ion-selective Electrodes (ISE)

See PASCO catalog or 

www.pasco.com

Oxidation Reduction Potential (ORP) Electrode CI-6716

1 8

Summary of Contents for PS-2170

Page 1: ...thane Tubing 60 cm long inch ID 640 023 6 Quick release Connectors qty 4 640 021 7 Tubing Connectors qty 4 640 030 8 Syringe 60 cc 699 166 Required Equipment PASPORT Interface1 1 PASPORT interfaces include the AirLink IW 4100 or PS 2005 Xplorer GLX PS 2002 Xplorer PS 2000 PowerLink PS 2001 and USB Link PS 2100 See PASCO catalog or www pasco com Optional Equipment Fast response Temperature Probe PS...

Page 2: ...e included syringe connect it to the sensor s pressure port using the included tubing and a quick release connector Follow the instructions below to set up the sensor with DataStudio software if you are using a computer or the Xplorer GLX if you are using it stand alone without a computer For detailed information about each of the multi sensor sensor s component sensors see pages 3 5 DataStudio Se...

Page 3: ... a fluid or place it in contact with an object The included stainless steel probe can be used in both dry conditions and in liquids such as water and other mild chemicals and solutions Tip For better chemical resistance use a Teflon cover CI 6549 Temperature Calibration The temperature measurement can be calibrated however for most applications cali bration is not necessary Use a two point calibra...

Page 4: ...se one of these methods to clean and restore it After any of these procedures soak the electrode in a pH 7 buffer solution for 30 minutes General Contamination Soak the electrode in 0 1 molar hydrochloric acid HCl for 15 minutes Protein Deposits Soak the electrode in a solution of 1 pepsin in 0 1 molar HCl Inorganic Deposits Rinse the electrode with 0 1 molar ethylene dinitric tetra acidic acid ED...

Page 5: ...ckwise to secure it If your apparatus has a barbed or tapered connec tor such as the included syringe plug it directly into the other end of the tubing If the apparatus has a quick release pressure port use another quick release connector on the other end of the tubing Use one of the included tubing connectors to connect the tubing to larger diame ter tubing or to a rubber stopper with a hole Note...

Page 6: ...ange 35 C to 135 C Accuracy 0 5 C Resolution 0 01 C or better Sensing Element 10 kΩ thermistor located in probe tip pH ISE ORP probe voltage Electrode Connector standard BNC Voltage Range 2000 mV to 2000 mV Voltage Resolution 0 1 mV pH Range 0 to 14 pH Resolution 0 001 Absolute Pressure Range 0 kPa to 700 kPa Accuracy 2 kPa Resolution 0 1 kPa Repeatability 1 kPa Voltage Range 10 V to 10 V Accuracy...

Page 7: ...ve the Present Sensor Measurement and wait until it has stabilized 8 Click the Read From Sensor button for Point 1 9 Place the probe in the second known standard 10 Enter the known temperature or pH of the standard in the Standard Value field for Point 2 11 Observe the Present Sensor Measurement and wait until it has stabilized 12 Click the Read From Sensor button for Point 2 13 Click OK to accept...

Page 8: ...profit Reproduction under any other circumstances without the written consent of PASCO scientific is prohibited Trademarks PASCO PASCO scientific DataStudio MultiMeasure Sensors PASPORT Xplorer and Xplorer GLX are trademarks or registered trademarks of PASCO scientific in the United States and or in other countries All other brands products or service names are or may be trademarks or service mark...