TECHNICAL DETAILS : MODEL SWGB

             

   

           

 

 
Total Unit 
 
GAS 

OPERATING PRESSURE 

TOTAL HEAT INPUT (Net) 

NATURAL   G20 

20mb / 8” W.G. 

3.626 KW =  12372 Btu/h 

PROPANE G31 

37mb / 14.8” W.G 

4.263 KW =  14546 Btu/h 

BUTANE G30 

29mb/11.2” W.G. 

4.444 KW =  15162 Btu/h 

             

   

            

GAS RATE 

M³/HR 

FT³/HR 

LB/HR 

KG/HR 

NATURAL   
G20 

0.384 M³/HR 

13.550 FT³/HR 

 

 

PROPANE  
G31@ 37mb 

0.174 M³/HR 

6.159 FT³/HR 

0.677 LB/HR  0.307 KG/HR 

BUTANE 
G30@ 29mb 

0.138 M³/HR 

4.866 FT³/HR 

0.715 LB/HR  0.324 KG/HR 

AIR FLOW RATE FOR 
COMBUSTION 20m³/HR 

4.176 M³/HR 

 

 

 
Low Rate for all gases = 2.25KW 
 

Model  

 

Injector Size 

Injector Code 

SGWBP 

Propane G31 @ 37mbar 14.8” W.G. 
and Butane G30 

@ 29mbar 11.2” W.G. 

Burner Injector  

INJECT 119 

SGWB 

Nat Gas G20 @ 20mbar 8” W.G. 

Burner Injector  

INJECT 150 

                      

Water  temperature  rise  is  80°C  in  60 minutes  on  G31  and  G30  and  75°C  in  60 
minutes on G20 
 

Summary of Contents for SGWB

Page 1: ...INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS FAULT DIAGNOSTICS TECHNICAL DATA EXPLODED VIEW PARTS LIST WARRANTY INFORMATION Customer Information MODEL NUMBER ____________...

Page 2: ...nd Safety at Work Act Attention should be drawn to the fact that parts of this unit by necessity will get VERY HOT and will cause burns if touched accidentally Therefore it is the responsibility of th...

Page 3: ...6 2005 The products have been CE marked in compliance with the European Gas Directive 90 396 EEC The Parry Group have designed this range of units for use with the following gases and supply pressure...

Page 4: ...time This appliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which it is installed POSITI...

Page 5: ...ppliance All gas appliances must be fitted by a competent person to gas safety regulations in force Before the appliance is commissioned the gas safety regulations require that all connections on the...

Page 6: ...that the pilot flame has been established if not go back to step 3 6 If pilot flame is established keep knob depressed for 20 seconds then release 7 The pilot flame will continue to burn 8 Turn knob a...

Page 7: ...parts in this unit Cleaning Cleaning should be carried out by simply wiping the exterior of the appliance with a clean cloth and a small amount of detergent to remove any build up of fat deposits fro...

Page 8: ...y blocked injector Check clean injector Inadequate ventilation Check ventilation Burner faulty corroded blocked Check clean burner Replace as necessary Faulty flue system Check flue system Pilot will...

Page 9: ...R KG HR NATURAL G20 0 384 M HR 13 550 FT HR PROPANE G31 37mb 0 174 M HR 6 159 FT HR 0 677 LB HR 0 307 KG HR BUTANE G30 29mb 0 138 M HR 4 866 FT HR 0 715 LB HR 0 324 KG HR AIR FLOW RATE FOR COMBUSTION...

Page 10: ...ed out by a competent qualified person 1 Turn gas valve off disconnect unit 2 Place unit on side to expose wing nuts on under tray 3 Undo wing nuts 4 Lift under tray out 5 Undo the nut that attaches t...

Page 11: ...ctor has been changed the pilot must be adjusted to suit the alternate gas To do this remove bung on bottom of pilot assembly see image 10 Using a screwdriver adjust pilot jet to obtain a pilot flame...

Page 12: ...EF IN172 ISSUE No 1 DATE 30 10 09 Page 12 of 17 www parry co uk Model Injector Size Injector Code SGWBP Propane G31 37mbar 12 W G Burner Injector INJECT 119 SGWB Nat Gas G20 20mbar 8 W G Burner Inject...

Page 13: ...INSTRUCTION REF IN172 ISSUE No 1 DATE 30 10 09 Page 13 of 17 www parry co uk EXPLODED VIEW PARTS LIST...

Page 14: ...hole 1 12 Fixing Bracket 4 13 Spacer Bracket 4 14 Electrode ELECTRODE 1 15 Pilot PILOT3WAY 1 16 Thermocouple GWBTCOUPLE 1 17 Gas Knob KNOBPRO007 1 18 Gas Valve GWBAGASVALVE 1 19 Lower Plate 1 20 Inte...

Page 15: ...arranty During the warranty period it is at Parry s discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufacture...

Page 16: ...s arranged for service call and engineer refused access or customer not there No faults with the machine Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burne...

Page 17: ...ove will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled Any iss...

Reviews: